This paper presents the advantages of modifying the geometry of the sensing tip of a white-light, multimode optical fiber SPR sensor to optimize the dynamic range and sensitivity. By selectively beveling the distal end of the fiber probe, the wavelength of resonance can be redshifted by more than 100 nm and blue-shifted by more than 30 nm, This increases the flexibility of a white-light SPR sensor by increasing the dynamic range of accessible RIs and by shifting the resonance to the most sensitive regions of the detector. Sensitivity, measured in wavelength shift per RI change, can be increased by a factor of 4, Also, multiple-wavelength regions of SPR activity can simultaneously be observed on the same probe, thus increasing the information content of a SPR spectrum. [References: 35]
机译:本文介绍了修改白光,多模光纤SPR传感器的传感头几何形状以优化动态范围和灵敏度的优势。通过选择性地斜切光纤探头的远端,可以使共振波长红移超过100 nm,蓝移超过30 nm。这通过增加LED的动态范围而增加了白光SPR传感器的灵活性。可访问的RI,并通过将共振转移到检测器的最敏感区域。可以将每个RI变化的波长偏移测量的灵敏度提高4倍。此外,可以在同一探头上同时观察到SPR活性的多个波长区域,从而增加了SPR光谱的信息含量。 [参考:35]