...
首页> 外文期刊>Analytical chemistry >Desorption Electrospray lonization of Explosives on Surfaces:Sensitivity and Selectivity Enhancement by Reactive Desorption Electrospray lonization
【24h】

Desorption Electrospray lonization of Explosives on Surfaces:Sensitivity and Selectivity Enhancement by Reactive Desorption Electrospray lonization

机译:炸药在表面上的解吸电喷雾电离:通过反应性解吸电喷雾电离提高灵敏度和选择性

获取原文
获取原文并翻译 | 示例
           

摘要

Desorption electrospray ionization (DESI),an ambient mass spectrometry technique,is used for trace detection of the explosives trinitrohexahydro-l,3,5-triazine (RDX),octahydro-1,3,5,7-tetranitro-1,3,5,7-tetrazocine (HMX),2,4,6-trinitrotoluene (TNT),Pentaerythritol tetranitrate (PETN),and their plastic compositions (Composition C-4,Semtex-H,Detasheet) directly from a wide variety of surfaces (metal,plastic,paper,polymer) without sample preparation or pretreatment.Analysis of the explosives is performed under ambient conditions from virtually any surface in very short times (<5 s) including confirmatory tandem mass spectrometry (MS/MS) experiments,while retaining the sensitivity and specificity that mass spectrometry offers.Increased selectivity is obtained both by MS/MS and by performing additional experiments in which additives are included in the spray solvent.These reactive DESI experiments (reactions accompanying de-sorption) produce such ions as the chloride and trifluo-roacetate adducts of RDX and HMX or the Meisenheimer complex of TNT.Desorption atmospheric pressure chemical ionization,a variant of DESI that uses gas-phase ions generated by atmospheric pressure corona discharges of toluene or other organic compounds,provides evidence for a heterogeneous-phase (gaseous ion/absorbed analyte) charge-transfer mechanism of DESI ionization in the case of explosives.Plastic explosives on surfaces were analyzed directly as fingerprints,without sample preparation,to test DESI as a possible method for in situ detection of explosives-contaminated surfaces.DESI also allowed detection of explosives in complex matrixes,including lubricants,household cleaners,vinegar,and diesel fuel.Absolute limits of detection for the neat explosives were subnanogram in all cases and subprogram in the case of TNT.The DESI response was linear over 3 orders of magnitude for TNT.Quantification of RDX on paper gave a precision (RSD) of 2.3%.Pure water could be used as the spray solution for DESI,and it showed ionization efficiencies for RDX in the negative ion mode similar to that given by methanol/water.DESI represents a simple and rapid way to detect explosives in situ with high sensitivity and specificity and is especially useful when they are present in complex mixtures or in trace amounts on ordinary environmental surfaces.
机译:解吸电喷雾电离(DESI)是一种环境质谱技术,用于痕量检测炸药三硝基六氢-1,3,5-三嗪(RDX),八氢-1,3,5,7-四硝基-1,3,直接从各种表面(5,7-四唑辛(HMX),2,4,6-三硝基甲苯(TNT),季戊四醇四硝酸酯(PETN)及其塑料组合物(C-4,Semtex-H,Detasheet)(金属,塑料,纸张,聚合物),无需样品制备或预处理。炸药的分析是在环境条件下,几乎在任何短时间内(<5 s)在几乎任何表面上进行的,包括验证性串联质谱(MS / MS)实验,同时保留了通过质谱/质谱以及通过进行其他实验(其中将添加剂包含在喷雾溶剂中)获得了更高的选择性,这些反应性DESI实验(伴随解吸的反应)产生的离子如氯离子和三氟乙酸RDX和HMX的产物或TNT的Meisenheimer络合物。解吸大气压化学电离是DESI的一种变体,它使用由甲苯或其他有机化合物的大气压电晕放电产生的气相离子,提供了异相(气态)的证据。离子/吸收的分析物的电荷转移机制)。直接将表面上的塑料炸药作为指纹进行分析,无需准备样品,以测试DESI作为原位检测被炸药污染的表面的方法。还可以检测复杂基质中的爆炸物,包括润滑剂,家用清洁剂,醋和柴油。在所有情况下,纯净爆炸物的绝对检测极限是亚毫微克,在TNT情况下是子程序.DESI响应在3个数量级上呈线性纸上RDX的定量精度(RSD)为2.3%。纯水可用作DES的喷雾溶液I,它显示了在负离子模式下RDX的电离效率,类似于甲醇/水。DESI代表了一种简单,快速的方法,可以高灵敏度和高特异性就地检测爆炸物,当它们以复杂的形式存在时特别有用。普通环境表面上的混合物或痕量。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号