It was found that the fluorescence intensity of lanthanum (III) (La~(3+))-quercetin (Qu) complex is greatly enhanced by proteins in the presence of sodium dodecyl benzene sulfonate (SDBS).Based on this finding,a new fluorimetric method for the determination of proteins was developed.Under optimum conditions,the enhanced intensity of fluorescence is in proportion to the concentration of proteins in the range of 2.5 x 10~(-8) to 1.0 x 10~(-5) g/mL for bovine serum albumin (BSA),5.0 x 10~(-8) to 1.5 x 10~(-5)g/mL for human serum albumin (HSA),and 1.0 X 10~(-7) to 1.5 x 10~(-5)g/mL for egg albumin (EA).Their detection limits (S/N=3) are 5.0 x 10~(-9) g/mL,7.0 x 10~(-9)g/mL,and 2.1 x 10~(-8)g/mL,respectively.The interaction mechanism was also studied.
机译:研究发现,在十二烷基苯磺酸钠(SDBS)存在下,蛋白质能大大提高镧(La)(La〜(3 +))-槲皮素(Qu)配合物的荧光强度。发展了荧光测定蛋白质的方法。在最佳条件下,增强的荧光强度与蛋白质的浓度成正比,范围为2.5 x 10〜(-8)至1.0 x 10〜(-5)g /牛血清白蛋白(BSA)的mL为5.0 x 10〜(-8)至1.5 x 10〜(-5)g / mL人血清白蛋白(HSA)的1.0 x 10〜(-7)至1.5 x 10卵白蛋白(EA)约为(-5)g / mL,其检出限(S / N = 3)为5.0 x 10〜(-9)g / mL,7.0 x 10〜(-9)g / mL,分别为2.1 x 10〜(-8)g / mL。