首页> 外文期刊>Analytical Letters >ICP-MS Method Validation for the Analysis of Trace Elements in Illicit Heroin
【24h】

ICP-MS Method Validation for the Analysis of Trace Elements in Illicit Heroin

机译:非法海洛因中痕量元素分析的ICP-MS方法验证

获取原文
获取原文并翻译 | 示例

摘要

The analysis of the trace elements present in the street doses of heroin has currently been undertaken with a dual aim: to estimate the elemental compositions and to cluster the case samples. Inductively coupled plasma-mass spectrometry was optimized to quantify 18 trace elements simultaneously. The method presented high repeatability and reproducibility for the target elements. The linear concentration ranges achieved linearity with r ~2 > 0.9975. The limits of detection (LOD) were sufficiently low for almost all the elements except for Ca (LOD = 100 ppb). The limit of quantification (LOQ) for each element was also found acceptable. All target elements show mean recoveries between 92%-108%. Other major findings of this study including intra-sample (RSD < 5%) and inter-sample (RSD < 14%) precisions, sample weight test (≥30 mg), dissolution vessels, and sample filtration are also reported. The capability of the optimized method was assessed by using forty case samples. With their elemental compositions statistical classification of these case samples is also discussed herein.
机译:目前,对海洛因街头剂量中的痕量元素进行了分析,其双重目标是:估算元素组成并对病例样本进行聚类。优化了电感耦合等离子体质谱法,以同时量化18种痕量元素。该方法对目标元素具有很高的可重复性和可重复性。线性浓度范围达到线性,r〜2> 0.9975。除了Ca(LOD = 100 ppb)以外,几乎所有元素的检出限(LOD)都足够低。每个元素的定量限(LOQ)也被认为是可以接受的。所有目标元素的平均回收率在92%-108%之间。该研究的其他主要发现还包括样品内(RSD <5%)和样品间(RSD <14%)精度,样品重量测试(≥30mg),溶出杯和样品过滤。通过使用40个案例样本评估了优化方法的能力。本文还讨论了这些案例样本的元素组成统计分类。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号