首页> 外文期刊>Analytical chemistry >A cell-based bar code reader for high-throughput screening of ion channel-ligand interactions
【24h】

A cell-based bar code reader for high-throughput screening of ion channel-ligand interactions

机译:基于细胞的条形码阅读器,用于高通量筛选离子通道-配体相互作用

获取原文
获取原文并翻译 | 示例
获取外文期刊封面目录资料

摘要

This paper presents a microfluidics-patch clamp platform for performing high-throughput screening and rapid characterization of weak-affinity ion channel-ligand interactions. This platform integrates a microfluidic chip consisting of multiple channels entering an open volume with standard patch clamp equipment. The microfluidic chip is placed on a motorized scanning stage and the method relies on the ability to scan rapidly, on the order of milliseconds, a patch-clamped cell across discrete zones of different solutions created in the open volume. Under ideal conditions, this method has the capacity to obtain kinetically resolved patch clamp measurements and dose-response curves of up to 10(3) ligand solutions in a single day. [References: 23]
机译:本文提出了一种微流控膜片钳平台,用于执行高通量筛选和快速表征弱亲和性离子通道-配体相互作用。该平台集成了微流控芯片,该微流控芯片由多个通道组成,这些通道通过标准的膜片钳设备进入一个开放体积。将微流控芯片放置在电动扫描台上,该方法依赖于能够以毫秒为单位快速扫描跨开放空间中创建的不同解决方案的离散区域的膜片夹细胞的能力。在理想条件下,该方法能够在一天中获得多达10(3)个配体溶液的动力学解析的膜片钳测量值和剂量响应曲线。 [参考:23]