...
首页> 外文期刊>Cardiovascular and Interventional Radiology: A Journal of Imaging in Diagnosis and Treatment >MR-Guided High-Power Microwave Ablation in Hepatic Malignancies: Initial Results in Clinical Routine
【24h】

MR-Guided High-Power Microwave Ablation in Hepatic Malignancies: Initial Results in Clinical Routine

机译:MR-Liawed Hepatic Matignacies的高功率微波消融:临床常规的初始结果

获取原文
获取原文并翻译 | 示例
   

获取外文期刊封面封底 >>

       

摘要

Purpose Evaluation of technique effectiveness, patient safety and ablation parameters of MR-guided microwave ablation in hepatic malignancies using an MR-conditional high-power microwave ablation system. Materials and Methods Institutional review board approval and informed patient consent were obtained. Patients who underwent MR-guided microwave ablation of hepatic malignancies in a 1.5T wide-bore scanner using a perfusion-cooled high-power microwave ablation system with a maximum generator power of 150 W were included. Ablation parameters comprising procedure durations, net ablation duration, applicator positions and ablation zone dimensions were recorded. Adverse events were classified according to the CIRSE classification system. Technique effectiveness was assessed after 1 month. Follow-up was conducted with contrast-enhanced MRI and ranged from 1 to 20 months (mean: 6.1 +/- 5.4 months). Results Twenty-one consecutive patients (age: 63.4 +/- 10.5 years; 5 female) underwent 22 procedures for 28 tumours (9 hepatocellular carcinomas, 19 metastases) with a mean tumour diameter of 14.6 +/- 5.4 mm (range: 6-24 mm). Technique effectiveness was achieved in all lesions. Tumours were treated using 1.7 +/- 0.7 applicator positions (range: 1-3). Mean energy and ablation duration per tumour were 75.3 +/- 35.4 kJ and 13.3 +/- 6.2 min, respectively. Coagulation zone short- and long-axis diameters were 29.1 +/- 6.4 mm and 39.9 +/- 7.4 mm, respectively. Average procedure duration was 146.4 +/- 26.2 min (range: 98-187 min). One minor complication was reported. Five patients developed new tumour manifestations in the untreated liver. Local tumour progression was not observed during initial follow-up. Conclusion MR-guided high-power microwave ablation provides safe and effective treatment of hepatic malignancies with short ablation times and within acceptable procedure durations.
机译:目的评价磁共振引导下高功率微波消融系统治疗肝脏恶性肿瘤的技术有效性、患者安全性和消融参数。材料和方法获得机构审查委员会批准和患者知情同意。包括在1.5T宽口径扫描仪上,使用最大发电机功率为150W的灌注冷却高功率微波消融系统,在MR引导下对肝脏恶性肿瘤进行微波消融的患者。记录消融参数,包括手术持续时间、净消融持续时间、治疗探头位置和消融区尺寸。根据CIRSE分类系统对不良事件进行分类。1个月后评估技术效果。随访时间为1-20个月(平均6.1+/-5.4个月),采用对比增强MRI进行。结果21例患者(年龄:63.4+/-10.5岁;5名女性)接受了22次手术治疗28个肿瘤(9个肝细胞癌,19个转移瘤),平均肿瘤直径为14.6+/-5.4mm(范围:6-24mm)。所有病变均获得了技术有效性。使用1.7+/-0.7个治疗探头位置(范围:1-3)治疗肿瘤。每个肿瘤的平均能量和消融持续时间分别为75.3+/-35.4 kJ和13.3+/-6.2 min。凝固区的短轴和长轴直径分别为29.1+/-6.4mm和39.9+/-7.4mm。平均手术时间为146.4+/-26.2分钟(范围:98-187分钟)。报告了一个轻微的并发症。五名患者在未经治疗的肝脏出现了新的肿瘤表现。在最初的随访中未观察到局部肿瘤进展。结论MR引导下高功率微波消融治疗肝脏恶性肿瘤安全有效,消融时间短,持续时间短。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号