A new technique is described for the rapid and accurate measurement of electrophoretic mobilities of proteins in different solution environments using capillary electrophoresis. Data were obtained at- different pH using surface-modified capillaries to reduce nonspecific protein adsorption and using hydrodynamic mobilization to improve reproducibility and overall accuracy. The net protein charge and extent of anion binding were evaluated from the mobility data obtained in different pH and ionic environments for bovine serum albumin. The results were in good agreement with titration data obtained using ion.selective electrodes and mobility data obtained using free solution electrophoresis. The method requires extremely small amounts of protein (picogram quantities and nanoliter volumes) and is easily automated, making it very suitable for protein characterization and for initial screening of possible separation techniques.
机译:描述了一种新技术,用于使用毛细管电泳在不同溶液环境中快速准确地测量蛋白质的电泳迁移率。使用表面修饰的毛细管以减少非特异性蛋白质吸附,并使用流体动员以提高重现性和总体准确性,在不同pH值下获得数据。从在不同pH和离子环境下获得的牛血清白蛋白的迁移率数据评估净蛋白质电荷和阴离子结合程度。结果与使用离子选择性电极获得的滴定数据和通过自由溶液电泳获得的迁移率数据高度吻合。该方法仅需极少量的蛋白质(皮克数量和纳升体积),并且易于自动化,非常适合蛋白质表征和可能的分离技术的初步筛选。