The effects of mobile-phase additives and analyte concentration on electrospray ionization mass spectra of a series of tetracyclines were investigated in both positive and negative ion modes. Only [M + H](+) and [M - H](-) ions were observed. The greatest sensitivity as [M + H](+) ions was obtained with 1% acetic acid and the greatest sensitivity as [M - H](-) ions was obtained using 50 mM. ammonium hydroxide. Sensitivities in the positive ion mode were greater than those in the negative ion mode. The sensitivity as [M + H](+) showed no systematic variation with pH; however, the sensitivity as [M - H](-) did increase with increasing pH. A larger linear range was observed for [M - H](-) than for [M + H](+) ions. Both [M + Na](+) and [IM + H](+) ions were observed with 0.5 mM sodium acetate and sodium iodide, but no adduct ions were observed with ammonium acetate. Some M2H+ ions were observed at higher concentrations. Cluster ions, Na(NaOAc)(n)(+) or Na(NaI)(n)(+), but no sample ions were observed using 5 mM salts. The data suggest that mechanisms in addition to solution ionization are involved in the formation of the ESI sample ions. The utility of mobile phases containing 1% HOAc or 50 mM NH4OH was demonstrated for chromatographic separations. [References: 54]
机译:在正负离子模式下研究了流动相添加剂和分析物浓度对一系列四环素电喷雾电离质谱的影响。仅观察到[M + H](+)和[M-H](-)离子。用1%的乙酸获得最大的[M + H](-)离子灵敏度,使用50 mM获得最大的[M-H](-)离子灵敏度。氢氧化铵。正离子模式下的灵敏度大于负离子模式下的灵敏度。灵敏度为[M + H](+),没有显示随pH的系统变化;但是,[M-H](-)的敏感性确实随着pH值的增加而增加。与[M + H](+)离子相比,[M-H](-)的线性范围更大。用0.5 mM乙酸钠和碘化钠观察到[M + Na](+)和[IM + H](+)离子,但用乙酸铵未观察到加成离子。在较高浓度下观察到一些M2H +离子。簇离子Na(NaOAc)(n)(+)或Na(NaI)(n)(+),但使用5 mM盐未观察到样品离子。数据表明,除溶液电离外,其他机制还参与了ESI样品离子的形成。含有1%HOAc或50 mM NH4OH的流动相可用于色谱分离。 [参考:54]

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号