首页> 外文期刊>Biological & pharmaceutical bulletin >Incorrect Holding Angle of Dry Powder Inhaler during the Drug-Loading Step Significantly Decreases Output Efficiency
【24h】

Incorrect Holding Angle of Dry Powder Inhaler during the Drug-Loading Step Significantly Decreases Output Efficiency

机译:在药物负载步骤期间,干粉吸入器的保持角度不正确显着降低输出效率

获取原文
获取原文并翻译 | 示例
           

摘要

It is well known that correct use of inhalers plays a critical role in optimal inhalation therapy, but the impact of incorrect inhaler use on pulmonary drug delivery has not been quantitatively evaluated. The aim of this study was to investigate the frequency of holding inhalers at incorrect angles during the drug-loading step while using Turbuhaler (R) and to quantify the influence of the inhaler angle on in vitro pulmonary delivery. Thirty patients prescribed Turbuhaler (R) at Shiga University of Medical Science Hospital were enrolled. During inhalation, the participants' inhalation techniques were assessed by clinical pharmacists. Additionally, the influence of the inhaler angle on pulmonary delivery of budesonide via Symbicort (R) Turbuhaler (R) was investigated using a Twin-Stage Liquid Impinger. Output efficiency (OE), stage 2 deposition (St2), and OE x St2 were calculated. An incorrect angle during the drug-loading step was observed in 33.3% of the participants. In vitro testing demonstrated that OE, an index of the loaded dose, significantly decreased by 73.3% at an incorrect angle, while St2, an index of the deagglomerating efficiency, was stable independent of the holding angle. OE x St2, indicating the bronchial and pulmonary drug delivery amount, decreased by 76.9%. An incorrect holding angle reduced the loaded dose, resulting in decreased pulmonary delivery. Error in the inhaler angle occurs frequently and demonstrates a considerable impact on pulmonary drug delivery. Hence, it is necessary to assess the Turbuhaler (R) angle during inhalation.
机译:众所周知,正确使用吸入器在最佳吸入治疗中发挥着关键作用,但对吸入器对肺药递送的不正确使用的影响尚未定量评价。本研究的目的是在使用涡轮纳尔(R)的同时研究药物载荷步骤期间以不正确的角度保持吸入器的频率,并量化吸入角度对体外肺递送的影响。 Zhiga医学医院大学的三十名患者陷入困境。在吸入期间,通过临床药剂师评估参与者的吸入技术。另外,使用双级液体滴注研究了通过Symbicort(R)涡轮骨(R)的较哈尔角对肺递送的肺递送的影响。计算输出效率(OE),阶段2沉积(ST2)和OE X ST2。在33.3%的参与者中观察到药物负载步骤期间的不正确角度。体外测试证明,OE,负载剂量的指数,在不正确的角度下显着降低73.3%,而ST2是直伸效率的指数,与保持角度稳定。 OE X ST2,表示支气管和肺药递送量,减少76.9%。保持角度不正确降低负载剂量,导致肺部递送减少。吸入器中的误差经常发生并显示对肺药递送的相当大的影响。因此,有必要在吸入期间评估涡轮钟形(R)角度。

著录项

相似文献

  • 外文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号