Demonstration of four immunoassay formats using the array biosensor

机译:使用阵列生物传感器演示四种免疫测定形式

获取原文
获取原文并翻译 | 示例
           

摘要

The ability of a fluorescence-based array biosensor to measure and quantify the binding of an antigen to an immobilized antibody has been demonstrated using the four different immunoassay formats: direct, competitive, displacement, and sandwich. A patterned array of antibodies specific for 2,4,6-trinitrotoluene (TNT) was immobilized onto the surface of a planar waveguide and used to measure signals from different antigen concentrations simultaneously. For direct, competitive, and displacement assays, which are one-step assays, measurements were obtained in real time. Dose-response curves were calculated for all four assay formats, demonstrating the array biosensor's ability to quantify the amount of antigen present in solution. [References: 32]
机译:使用四种不同的免疫测定形式证明了基于荧光的阵列生物传感器测量和定量抗原与固定化抗体结合的能力:直接,竞争,置换和三明治。将对2,4,6-三硝基甲苯(TNT)特异的抗体图案阵列固定在平面波导的表面上,并用于同时测量来自不同抗原浓度的信号。对于直接分析,竞争分析和置换分析,它们是一步式分析,它们是实时获得的。计算了所有四种测定形式的剂量反应曲线,证明了阵列生物传感器对溶液中存在的抗原量进行定量的能力。 [参考:32]