Miniaturized, disposable amperometric biosensors for determination of creatinine in human serum are described. The base electrodes are fabricated using microelectronics techniques, to build a multilayer film structure on a polyimide foil, By using a thin electropolymerized film of poly(1,3-diaminobenzene), the electrochemical interferences from ascorbate, urate, acetaminophen, and other oxidizable species are greatly diminished, The multienzyme system (creatininase, creatinase, sarcosine oxidase) is immobilized on top of the permselective layer using cross-linking of the proteins with glutaraldehyde. The electropolymerization conditions for obtaining almost ideal permselectivity of the inner layer are defined, as well as the optimal enzyme layer preparation, A composite polymeric outer membrane [Nafion + poly-(2-hydroxy-ethyl methacrylate)] is used for diffusion control and to protect the enzyme layer from fouling. The reagentless planar sensors for creatinine and creatine have fast response time (t(95) = 1 min), linear response up to 1.2 mM in batch-type and 2,0 mM in flow injection analysis and a detection limit of 10-20 mu M. They are applied in a differential setup for creatinine assay in control and hospital human serum samples and are suitable for incorporation in a portable analyzer.
机译:描述了用于测定人血清中肌酸酐的小型化的一次性安培生物传感器。使用微电子技术制造基础电极,以在聚酰亚胺箔上构建多层膜结构。通过使用聚(1,3-二氨基苯)薄的电聚合膜,抗坏血酸盐,尿酸盐,对乙酰氨基酚和其他可氧化物质的电化学干扰大大减少了这种情况,通过蛋白质与戊二醛的交联,将多酶系统(肌酐酶,肌酐酶,肌氨酸氧化酶)固定在渗透选择性层的顶部。定义了获得几乎理想的内层渗透选择性的电聚合条件,以及最佳的酶层制备方法。复合聚合物外膜[Nafion +聚-(甲基丙烯酸2-羟基乙酯)]用于扩散控制,以及保护酶层不受污染。用于肌酐和肌酸的无试剂平面传感器具有快速响应时间(t(95)= 1分钟),批处理类型的线性响应高达1.2 mM,流动注射分析的线性响应高达2,0 mM,检测限为10-20μm M.它们可用于对照和医院人血清样品中肌酐测定的差异设置,适合掺入便携式分析仪中。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号