首页> 外文期刊>Analytical chemistry >Simultaneous determination of trace levels of nine haloacetic acids in biological samples as their pentafluorobenzyl derivatives by gas chromatography/tandem mass spectrometry in electron capture negative ion chemical ionization mode
【24h】

Simultaneous determination of trace levels of nine haloacetic acids in biological samples as their pentafluorobenzyl derivatives by gas chromatography/tandem mass spectrometry in electron capture negative ion chemical ionization mode

机译:电子捕获负离子化学电离模式下的气相色谱/串联质谱法同时测定生物样品中五氟苄基衍生物中的九种卤乙酸的痕量

获取原文
获取原文并翻译 | 示例
           

摘要

Haloacetic acids (HAAS) are environmentally and medically important chemicals. No analytical method is currently available to analyze EPA-regulated HAAs in biological samples at environmentally relevant low concentrations. Clinical studies of this class of chemicals are also limited by the lack of analytical techniques of high sensitivity and precision. We now report a new analytical method using gas chromatography/ion trap mass spectrometry for quantifying nine HAAS present in plasma, urine, and water at picogram per milliliter levels. The derivatization reactions of HAAs with pentafluorobenzyl bromide were optimized and detection with an electron capture negative ion chemical ionization mode was employed to enhance the sensitivity. Selected ion monitoring and selected reaction monitoring methods were utilized for quantitation. The detection limits of HAAS in plasma, urine, and water were 25-1000 pg/mL. Accuracies varied from 86.6 to 118.1% (intraday). and 81.7 to 119.6% (interday). Precisions (CV) varied from 0.9 to 19.9% (intraday) and 0.8 to 19.8% (interday), and linearities (r(2)) varied from 0.9732 to 0.9998 (intraday) and 0.9422 to 0.9987 (interday), respectively. Methyl tertbutyl ether and diethyl ether provided the highest extraction recoveries for the HAAs (74.9-107.2%). The method was applied successfully to a kinetic investigation of low levels of HAAs in humans consuming chlorinated drinking water. [References: 67]
机译:卤乙酸(HAAS)是对环境和医学很重要的化学物质。当前没有可用的分析方法来分析与环境相关的低浓度的生物样品中EPA调节的HAA。由于缺乏高灵敏度和高精度的分析技术,此类化学药品的临床研究也受到限制。现在,我们报告一种使用气相色谱/离子阱质谱技术分析血浆,尿液和水中存在的9种HAAS​​(每毫升皮克级)的新分析方法。优化了HAAs与五氟苄基溴的衍生化反应,并采用电子捕获负离子化学电离模式进行检测,以提高灵敏度。使用选定的离子监测和选定的反应监测方法进行定量。血浆,尿液和水中HAAS的检出限为25-1000 pg / mL。准确性(日内)从86.6%到118.1%不等。和81.7至119.6%(日间)。精度(CV)从0.9%至19.9%(日间)和0.8%至19.8%(日间)不等,线性度(r(2))分别从0.9732至0.9998(日间)和0.9422至0.9987(日间)变化。甲基叔丁基醚和乙醚为HAA提供了最高的萃取回收率(74.9-107.2%)。该方法已成功地用于人体消耗氯化饮用水中低水平HAAs的动力学研究。 [参考:67]

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号