An on-line method was developed for the extraction, cleanup, and analysis of airborne organophosphate esters collected on glass fiber filters. The extraction and cleanup step was performed by conducting the dynamic microwave-assisted extraction (DMAE) coupled to solid-phase extraction (SPE). This system was further connected to include large-volume injection gas chromatography. The Injection interface was a programmable temperature vaporizer. The system performance test was investigated using spiked glass fiber filters. The DMAE-SPE recovery of the organophosphate esters was found to be greater than 97%. The repeatability of the uncorrected peak areas and the retention times was determined to be 4.2-8.0 and 0.03% relative standard deviation, respectively, and limits of detection were in the range 61-186.2 pg/m(3). The method was tested in a newly restored office, in which several of the targeted organophosphate esters were detected. The total sampling and analysis time was less than 1.5 h. [References: 24]
机译:开发了一种在线方法,用于玻璃纤维过滤器上收集的空气中有机磷酸酯的提取,净化和分析。通过进行与固相萃取(SPE)耦合的动态微波辅助萃取(DMAE)进行萃取和净化步骤。该系统进一步连接以包括大体积进样气相色谱。注入接口是可编程的温度蒸发器。使用尖刺的玻璃纤维过滤器研究了系统性能测试。发现有机磷酸酯的DMAE-SPE回收率大于97%。未校正峰面积和保留时间的重复性分别确定为4.2-8.0和0.03%相对标准偏差,并且检出限在61-186.2 pg / m(3)范围内。该方法在新近修复的办公室中进行了测试,其中检测到几种目标有机磷酸酯。总采样和分析时间少于1.5小时。 [参考:24]

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号