The use of high performance liquid chromatography coupled with inductively coupled plasma mass spectrometry (HPLC-ICPMS) as means for the quantitative determination of ZD0473, a platinum anticancer drug, and its related biologically active "aqua" compounds in biofluid samples is described. The performance of the resulting HPLC-ICPMS method was compared with that of a conventional HPLC-triple quadrupole mass spectrometer-based (HPLC-MS/MS) system for properties such as limit of detection, linearity, and reproducibility using spiked samples. The methods were then applied to the determination of plasma ultrafitrate concentrations of ZD0473 in dog plasma samples obtained following intravenous and oral administration at 0.5 and 6 mg/kg, respectively. These experiments showed that both methods were capable of providing accurate and precise results but that the HPLC-ICPMS method had advantages of extended linear range and superior sensitivity, providing a limit of quantification of 0.1 ng/mL for ZD0473, as compared to 5 ng/mL using the current HPLC-MS/MS method. In addition, by using a single combined HPLC-ICPMS/MS/MS system, it was possible to determine the relative MS/MS response of the aqua compounds for the first time. [References: 17]
机译:描述了使用高效液相色谱结合电感耦合等离子体质谱法(HPLC-ICPMS)作为定量测定生物流体样品中ZD0473(一种铂类抗癌药)及其相关生物活性“水”化合物的方法。将所得HPLC-ICPMS方法的性能与基于常规HPLC-三重四极杆质谱仪(HPLC-MS / MS)的系统的性能进行了比较,例如使用加标样品的检测限,线性和重现性。然后将这些方法分别用于分别以0.5和6 mg / kg静脉和口服给药后,测定狗血浆样品中ZD0473的血浆超适合浓度。这些实验表明,两种方法均能够提供准确和精确的结果,但是HPLC-ICPMS方法具有扩展的线性范围和出色的灵敏度的优势,与5 ng / mL相比,ZD0473的定量限为0.1 ng / mL。使用当前的HPLC-MS / MS方法洗脱2 mL。此外,通过使用单个HPLC-ICPMS / MS / MS组合系统,可以首次确定水化合物的相对MS / MS响应。 [参考:17]

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号