...
首页> 外文期刊>Applied optics >Optimized laser-induced breakdown spectroscopy for determination of xenobiotic silver in monosodium glutamate and its verification using ICP-AES
【24h】

Optimized laser-induced breakdown spectroscopy for determination of xenobiotic silver in monosodium glutamate and its verification using ICP-AES

机译:优化激光诱导的击穿光谱法测定谷氨酸单钠银中的异黄银及其使用ICP-AES的验证

获取原文
获取原文并翻译 | 示例
   

获取外文期刊封面封底 >>

       

摘要

Laser-induced breakdown spectroscopy (LIBS) was applied as a potential tool for the determination of xenobiotic metal in monosodium glutamate (MSG). In order to achieve a high-sensitivity LIBS system required to determine trace amounts of metallic silver in MSG and to attain the best detection limit, the parameters used in our experiment (impact of focusing laser energy on the intensity of LIBS emission signals, the influence of focusing lens distance on the intensity of LIBS signals, and time responses of the plasma emissions) were optimized. The spectra of MSG were obtained in air using a suitable detector with an optical resolution of 0.06 nm, covering a spectral region from 220 to 720 nm. Along with the detection of xenobiotic silver, other elements such as Ca, Mg, S, and Na were also detected in MSG. To determine the concentration of xenobiotic silver in MSG, the calibration curve was plotted by preparing standard samples having different silver abundances in an MSG matrix. The LIBS results of each sample were cross-verified by analyzing with a standard analytical technique such as inductively coupled plasma-atomic emission spectroscopy (ICP-AES). Both (LIBS and ICP-AES) results were in mutual agreement. The limit of detection of the LIBS setup was found to be 0.57 ppm for silver present in MSG samples. (C) 2018 Optical Society of America
机译:激光诱导的击穿光谱(Libs)作为测定谷氨酸钠(MSG)中的异黄素金属的潜在工具。为了实现MSG中的痕量金属银和获得最佳检测限所需的高灵敏度libs系统,我们实验中使用的参数(将激光能量对LIBS发射信号强度的影响,影响优化了对Libs信号强度的透镜距离,并优化了等离子体排放的时间响应)。使用具有0.06nm的光学分辨率的合适检测器在空气中获得MSG的光谱,覆盖220至720nm的光谱区域。随着异卵银的检测,在MSG中也检测到诸如Ca,Mg,S和Na的其他元素。为了确定MSG中的十二生物银的浓度,通过在MSG基质中制备具有不同银丰的标准样品来绘制校准曲线。通过用标准分析技术(例如电感耦合等离子体原子发射光谱(ICP-AES)分析,通过分析所述每个样品的LIB结果进行交叉验证。 (LIBS和ICP-AES)结果都在相互协议中。发现Libs设置的检测限为MSG样本中存在的银为0.57ppm。 (c)2018年光学学会

著录项

  • 来源
    《Applied optics》 |2018年第12期|共7页
  • 作者

    Rehan I.; Gondal M. A.; Rehan K.;

  • 作者单位

    Fed Urdu Univ Arts Sci &

    Technol Dept Appl Phys Islamabad 44000 Pakistan;

    King Fahd Univ Petr &

    Minerals Phys Dept Laser Res Grp POB 5047 Dhahran 31261 Saudi Arabia;

    Fed Urdu Univ Arts Sci &

    Technol Dept Appl Phys Islamabad 44000 Pakistan;

  • 收录信息
  • 原文格式 PDF
  • 正文语种 eng
  • 中图分类 应用;
  • 关键词

获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号