首页> 外文期刊>Applied optics >AuAg alloy film-based colorful SPR imaging sensor for highly sensitive immunodetection of benzo[a]pyrene in water
【24h】

AuAg alloy film-based colorful SPR imaging sensor for highly sensitive immunodetection of benzo[a]pyrene in water

机译:基于Auag合金薄膜的彩色SPR成像传感器,用于高度敏感的免疫免疫苯并[a]芘在水中

获取原文
获取原文并翻译 | 示例
           

摘要

A colorful surface plasmon resonance imaging (SPRi) sensor with the hue-based enhanced sensitivity has been developed by using sputtered AuAg alloy thin film as the sensing layer. The condition for optimizing the hue-based sensitivity of the SPRi sensor was achieved, that is, the initial resonance wavelength is in the range from 595 to 610 nm. Under this condition, the hue-based refractive index sensitivity of the SPRi sensor was measured as high as Delta hue/Delta n(c) = 29879/ RIU. This sensitivity is 8 times higher than that obtained with a gold-layer SPRi sensor (Delta hue/Delta n(c) = 3658/RIU) and 7.7 times as high in magnitude as the spectral sensitivity of the same sensor (Delta lambda(R)/Delta n(c) = 3897.6 nm/RIU). After functionalization of the AuAg alloy film with the monodonal antibody, the sensor was used for quantitative immunodetection of highly carcinogenic benzo[a]pyrene (BaP) in water. According to the experimental results, the average hue of the SPR color image (300 pixels x 300 pixels) experiences an initial rapid increase and then stabilizes 15 min after exposure of the functionalized AuAg alloy film to an aqueous BaP solution sample. The variation of average hue obtained at the equilibrium of surface immunoreaction is a linear function of BaP concentration with the slope being Delta hue/Delta c = 132.2/(mu g . L-1). A cooled CCD camera is able to distinguish a change of Delta hue = 1, offering the colorful SPRi sensor the BaP detection limit of 0.01 mu g . L-1. The comparative measurements of the sensor's responses indicate that the hue variation obtained with 0.1 mu g . L-1 of BaP is equal to that obtained either with 5 mu g . L-1 of benzanthracene or with 5 mu g . L-1 of benzofluoranthene, revealing the sensor's excellent specificity to BaP. The work demonstrated that the AuAg alloy film-based colorful SPRi sensor can be used not only for visualized analysis of molecular interaction at the surface but also for quantitative trace detection of small-molecule analytes. (C) 2019 Optical Society of America
机译:通过使用溅射的Auag合金薄膜作为感测层,开发了具有色调增强灵敏度的彩色表面等离子体共振成像(SPRI)传感器。实现了优化SPRI传感器的基于HUE的灵敏度的条件,即,初始共振波长在595至610nm的范围内。在这种情况下,测量SPRI传感器的基于色调的折射率敏感性,高达Delta Hue / delta n(c)= 29879 / Ruu。这种灵敏度比用金层SPRI传感器(Delta Hue / Delta N(c)= 3658 / Riu)获得的8倍,以及与同一传感器的光谱灵敏度高7.7倍(Delta lambda(r )/ delta n(c)= 3897.6 nm / riu)。在用单阳极抗体官能化uAg合金膜的官能化之后,该传感器用于在水中的高致癌苯并[a]芘(Bap)的定量免疫。根据实验结果,SPR彩色图像(300像素×300像素)的平均色调经历初始快速增加,然后在官能化的Auag合金膜暴露到水性壳体水溶液后稳定15分钟。在表面免疫反应平衡下获得的平均色调的变化是弯曲浓度的线性函数,斜坡是δ色调/δc= 132.2 /(mu g。l-1)。冷却的CCD摄像机能够区分Delta Hue = 1的变化,提供彩色Spri传感器的BAP检测限为0.01μmg。 L-1。传感器的反应的比较测量表明,用0.1μg获得的色调变化。 L-1的BaP等于用5μg获得的。 L-1苄丙烯或5亩g。 L-1的苯并氟蒽,揭示了传感器对BAP的优异特异性。该工作证明,基于Auag合金薄膜的彩色SPRI传感器不仅可以用于表面在表面的分子相互作用的可视化分析,而且用于测量小分子分析物的定量痕量检测。 (c)2019年光学学会

著录项

  • 来源
    《Applied optics》 |2019年第25期|共7页
  • 作者单位

    Chinese Acad Sci Inst Elect State Key Lab Transducer Technol Beijing 100190 Peoples R China;

    Chinese Acad Sci Inst Elect State Key Lab Transducer Technol Beijing 100190 Peoples R China;

    Chinese Acad Sci Inst Elect State Key Lab Transducer Technol Beijing 100190 Peoples R China;

    Chinese Acad Sci Inst Elect State Key Lab Transducer Technol Beijing 100190 Peoples R China;

    Chinese Acad Sci Inst Elect State Key Lab Transducer Technol Beijing 100190 Peoples R China;

    Chinese Acad Sci Inst Elect State Key Lab Transducer Technol Beijing 100190 Peoples R China;

  • 收录信息
  • 原文格式 PDF
  • 正文语种 eng
  • 中图分类 应用;
  • 关键词

获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号