An experimental study on the melting behavior of paraffin wax used as a phase change material (PCM) in a conical coil latent heat energy storage unit (LHSU) was performed. The experiments were conducted concurrently for conical coil and normal coil LHSUs to compare their thermal performances. The effect of heat transfer fluid (HTF) inlet temperature was examined. The evolution of the temperature during charging, the spatial variation in temperatures and captured images of the melting PCM in both LHSUs were compared. The results indicated that the melting rate in the conical coil LHSU was enhanced by 20.97%, 22.13% and 28.32% in comparison with that of normal coil LHSU at HTF inlet temperature of 70 degrees C, 75 degrees C and 80 degrees C respectively. Moreover, the rate of energy stored in the conical coil LHSU was a notably faster than that of the normal coil LHSU. The HTF inlet temperature has a similar effect on both LHSUs by substantially decreasing their melting time.
机译:进行了用作锥形线圈潜热能储存单元(LHSU)中用作相变材料(PCM)的石蜡蜡的实验研究。 实验同时进行锥形线圈和正常线圈LHSU,以比较它们的热性能。 检查了传热流体(HTF)入口温度的效果。 比较了在充电期间的温度的演变,比较了两种LHSU中熔化PCM的温度和捕获图像的空间变化。 结果表明,与70℃,75℃和80℃的HTF入口温度的正常线圈LHSU相比,锥形线圈LHSU中的熔化率增强了20.97%,22.13%和28.32%。 此外,存储在锥形线圈LHSU中的能量速率比正常线圈LHSU的能量值得注于。 通过显着降低它们的熔化时间,HTF入口温度对两个LHSU具有类似的效果。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号