摘要

The operation of R290 air conditioners at cold ambient temperatures can lead to sub-atmospheric suction pressures, risking the safety and reliability of such air conditioners. In this study, the effects of several system control strategies on the startup characteristics were investigated, with the goal of avoiding vacuums in air conditioners. The variations in the degrees of superheating and the changes in the flow patterns at key points were analyzed. The refrigerant migrations and pressure variations indicated that owing to the higher initial temperatures in a warm startup, the heat inertia of the compressor and indoor heat exchanger contributed to the formation of liquid refrigerant at the expansion valve inlet, as well as an increase in the suction pressure. Moreover, using larger initial expansion valve openings or a bypass tube between discharge and suction could increase the minimum suction pressures, by providing more R290 refrigerant to the low-pressure side at the beginning of startup.
机译:冷环境温度下R290空调的操作可导致亚大气压吸入压力,危险这种空调的安全性和可靠性。在这项研究中,研究了几种系统控制策略对启动特性的影响,目的是避免空调中真空。分析了过热程度的变化和关键点处的流动模式的变化。制冷剂迁移和压力变化表明,由于温暖启动中的初始温度较高,压缩机和室内热交换器的热惯性有助于在膨胀阀入口处形成液体制冷剂,以及吸力的增加压力。此外,通过在启动开始时向低压侧提供更多R290制冷剂,使用放电和抽吸之间的初始膨胀阀开口或旁路管可以增加最小抽吸压力。