In this paper, the effects of ground surface boundary conditions, especially diurnal shading, on performance of horizontal ground source heat pump (GSHP) systems were studied. Firstly, a GSHP system model, which consists of the heat transfer of horizontal ground heat exchangers (GHEs) and the integration of the heat pump, and the ground surface boundary model are introduced. The diurnal shading model for canyon streets is also introduced. Then, effects of ground surface boundary conditions and shading on horizontal GSHP systems are studied. Results show that different assumptions on ground surface boundary conditions have significant impact on outcomes and should carefully be considered during analysing. The outlet fluid temperature and fluctuation in North-South (N-S) streets are higher than those of East-West (E-W) streets. The increase in street aspect ratios and latitudes could decrease sunshine exposure time of the streets. Daily variations of solar radiation and shading influence the outlet temperatures of horizontal GHEs up to buried depth of 2.5 m. Therefore, the effects of solar radiation and shading should be considered when studying shallow horizontal GHEs.
机译:本文研究了地面边界条件,尤其是昼夜遮阳,对水平地面源热泵(GSHP)系统性能的影响。首先,引入了GSHP系统模型,其包括水平接地热交换器(嘴)的传热和热泵的集成以及地面边界模型。还介绍了峡谷街道的昼夜着色模型。然后,研究了地面边界条件和阴影对水平GSHP系统的影响。结果表明,地面边界条件的不同假设对结果产生了重大影响,并在分析期间仔细考虑。南北(N-S)街道的出口流体温度和波动高于东西(E-W)街道。街道纵横比和纬度的增加可能会降低街道的阳光暴露时间。日常变化的太阳辐射和阴影会影响水平灌水的出口温度,埋入2.5米的埋深深度。因此,在研究浅水灌水时,应考虑太阳辐射和遮光的影响。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号