In this paper, the mass flow rate characteristics of R245fa refrigerant flowing through electronic expansion valves (EEV) under varying operating conditions are studied experimentally. It is found that the mass flow rate increases with increasing EEV opening, condensing temperature, subcooling temperature, and orifice diameter. Based on the measured experimental data, two empirical correlations for mass flow rate prediction of R245fa through EEVs are proposed using the power-law correlation and the polynomial fit correlation. Predicted data of the polynomial fit method showed more consistency with the experimental results compared to that of power-law correlation, and 96.6% of the predicted mass flow rates deviate from the experimental data within 10%. (C) 2017 Elsevier Ltd. All rights reserved.
机译:本文通过实验研究了在不同操作条件下流过电子膨胀阀(EEV)的R245FA制冷剂的质量流量特性。 发现质量流量随着EEV的增加,冷凝温度,过冷温度和孔口直径而增加。 基于测量的实验数据,利用电力定律相关性和多项式拟合相关性提出了通过EEV的R245FA的质量流量预测的两个经验相关性。 与动力定律相关相比,多项式拟合方法的预测数据显示出更稠度的与实验结果相比,96.6%的预测质量流速偏离了10%以内的实验数据。 (c)2017 Elsevier Ltd.保留所有权利。