This study reports a fast, sensitive, and selective column switching ultrahigh-performance liquid chromatography-tandem mass spectrometry (UHPLC-MS/MS) method to determine the endocannabinoids (eCBs), anandamide (AEA), and 2-arachidonoylglycerol (2-AG) in plasma samples. This bidimensional system used a restricted access media column (RP-8 ADS, 25 mm x 4 mm x 25 mu M) in the first dimension and a core-shell Kinetex C18 (100 mm x 2, 1.7 mm x 1 mu M) column in the second dimension, followed by detection in a mass spectrometer triple quadrupole (multiple reactions monitoring mode) operating in the positive mode. RP-8 ADS was used for trace enrichment of eCBs (reverse phase partitioning) and macromolecular matrix size exclusion; the core-shell column was used for the chromatographic separation. The column switching UHPLC-MS/MS method presented a linear range spanning from 0.1 ng mL(-1) (LOQ) to 6 ng mL(-1) for AEA and from 0.04 ng mL(-1) (LOQ) to 10 ng mL(-1) for 2-AG. Excluding the LLOQ values, the precision assays provided coefficients of variation lower than 8% and accuracy with relative standard error values lower than 14%. Neither carryover nor matrix effects were detected. This high-throughput column switching method compared to conventional methods is time saving as it involves fewer steps, consumes less solvent, and presents lower LLOQ. The column switching UHPLC-MS/MS method was successfully applied to determine AEA and 2-AG in plasma samples obtained from Alzheimer's disease patients.
机译:本研究报告了快速,敏感和选择性的柱切换超高性能液相色谱 - 串联质谱(UHPLC-MS / MS)方法,以确定内胆碱(ECB),Anandamide(AEA)和2- arachidonoylgycerol(2-Ag )在血浆样品中。该双压系统在第一尺寸和核心壳Kinetex C18(100mm x 2,100m×1μm)柱中使用限制的接入介质柱(RP-8 ADS,25mm×4mm×25μm)在第二尺寸中,然后在质谱仪中检测在正模式下操作的质谱仪三极杆(多重反应监测模式)。 RP-8 ADS用于核心ECBS(反相分区)和大分子基质尺寸排除的富集;核心壳柱用于色谱分离。柱切换UHPLC-MS / MS方法呈现为AEA的0.​​1 ng mL(-1)(LOQ)至6 ng ml(-1)的线性范围,以及0.04 ng ml(-1)(loq)至10 ng ml(-1)2%。除了LLOQ值之外,精确测定提供了低于8%的变化系数,并且具有低于14%的相对标准误差值的精度。既未检测到携带和矩阵效应。这种高吞吐柱切换方法与传统方法相比是节省时间,因为它涉及更少的步骤,消耗更少的溶剂,并且呈下LLOQ。柱切换UHPLC-MS / MS方法成功地应用于从阿尔茨海默病患者获得的血浆样品中测定AEA和2-AG。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号