首页> 外文期刊>Analytica chimica acta >A paper-based analytical device coupled with electrochemical detection for the determination of dexamethasone and prednisolone in adulterated traditional medicines
【24h】

A paper-based analytical device coupled with electrochemical detection for the determination of dexamethasone and prednisolone in adulterated traditional medicines

机译:一种基于纸种的分析装置,其掺入电化学检测,用于测定掺孔传统药物中的地塞米松和泼尼松酮

获取原文
获取原文并翻译 | 示例
       

摘要

The adulteration of herbal medicines by dexamethasone or prednisolone is regarded as a serious problem in many communities. Herein, a novel platform for the separation and quantification of both target steroids in herbal medicines based on electrochemical paper-based analytical devices (ePADs) has been created. The ePAD was composed of Whatman SG81 chromatography paper, 3D-printed devices and a commercial screen-printed electrode. Whatman SG81 silica-coated paper was used for the separation of dexamethasone and prednisolone based on the difference in their partition coefficients during the flow of the mobile phase. The optimal mobile phase was composed of 60% ethyl acetate in cyclohexane and required 7min for separation. The separated steroids on the paper were then quantified by electrochemical detection using differential pulse voltammetry, in which the 3D-printed devices facilitated the measurement. Analytical detection ranges of 10-500 mu g mL(-1) were obtained for both dexamethasone and prednisolone (r(2) =0.988 and 0.994, respectively). The limits of detection for dexamethasone and prednisolone were 3.59 and 11.98 mu g mL(-1), respectively, whereas the limits of quantification were 6.00 and 20.02 mu g mL(-1), respectively. The amounts of both target steroids derived from real herbal medicine samples determined by the proposed method were comparable to those obtained with assays using standard high-performance liquid chromatography. In addition, a simple evaporation step can be used to increase the concentration of the samples before analysis. These ePADs are simple, low-cost, rapid, and very promising for on-site quantitative detection. (C) 2019 Elsevier B.V. All rights reserved.
机译:地塞米松或泼尼松龙的草药掺杂被认为是许多社区中的严重问题。在此,已经产生了基于电化学纸的分析装置(EPADS)在草药中分离和定量靶样类固醇的新颖平台。 EPAD由Whatman SG81色谱纸,3D印刷装置和商用屏幕印刷电极组成。 Whatman SG81二氧化硅涂布纸用于基于流动相流动期间其分区系数的差异分离地塞米松和泼尼松苷。最佳流动相由环己烷的60%乙酸乙酯组成,需要7分钟进行分离。然后通过使用差分脉冲伏安法通过电化学检测量化纸上的分离类固醇,其中3D印刷装置便于测量。对于地塞米松和泼尼松酮(R(2)= 0.988和0.994,分析检测范围为10-500 mu Gml(-1)。地塞米松和泼尼松龙的检测限率分别为3.59和11.98μg(-1),而定量限值分别为6.00和20.02μg(-1)。由所提出的方法测定的真正草药样品衍生的靶样类固醇的量与使用标准高效液相色谱法测定的方法相当。另外,可以使用简单的蒸发步骤来增加分析之前样品的浓度。这些时期简单,低成本,快速,非常有前途的现场定量检测。 (c)2019年Elsevier B.V.保留所有权利。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号