A new sample loading procedure was developed for isotope ratio measurements of ultratrace amounts of plutonium with thermal ionization mass spectrometry (TIMS). The goal was to determine the efficacy of a polymer fiber architecture for TIMS sample loading by following similar sample loading procedures as those used in bead loading. Fibers with diameter of approximately 100 mu m were prepared from triethylamine-quaternized-poly(vinylbenzyl chloride) cross linked with diazabicyclo[2.2.2]octane. Fiber sections (2.5 mm) were loaded with 10 pg of New Brunswick Laboratory certified reference material (NBL CRM) 128 from an 8 M HNO3 matrix and affixed to rhenium filaments with collodion. A single filament assembly was used for these analyses. Total ion counts (Pu-239 + Pu-242) and isotope ratios obtained from fiber-loaded filaments were compared to those measured by depositing Pu amended resin beads on the filament. Fiber loading was found to improve sensitivity, accuracy, and precision of isotope ratio measurements of plutonium when compared to the established resin bead loading method, while maintaining its simplicity. The average number of detected Pu+ counts was 180% greater, and there was a 72% reduction in standard deviation of ratio measurements when using fiber loading. An average deviation of 0.0012 (0.117%) from the certified isotope ratio value of NBL CRM Pu128 was measured when fiber loading versus a deviation of 0.0028 (0.284%) when bead loading. The fiber formation method presented in this study can be extended to other anion-exchange polymer chemistries and, therefore, offers a convenient platform to investigate the efficacy of novel polymer chemistries in sample loading for TIMS.
机译:开发了一种新的样品加载程序,用于同位素比率测量超速电离质谱(TIM)。目标是通过以下类似的样品加载程序确定聚合物纤维架构的疗效,以通过与珠子加载中使用的类似样品加载程序。用与二氮杂双环[2.2.2]辛烷连接的三乙胺 - 季铵化 - 聚(乙烯基苄氯丙酰氯)混合制备直径约100μm的纤维。纤维部分(2.5 mm)用10 pg新的Brunswick实验室认证的参考材料(NBL CRM)128,来自8M HNO3基质,并用胶合剂固定到铼长丝中。使用单丝组件用于这些分析。将总离子计数(PU-239 + PU-242)和由纤维加载的长丝获得的同位素比进行比较,通过在长丝上沉积PU修正的树脂珠粒测量的那些。发现纤维载量提高与已建立的树脂珠子加载方法相比,提高同位素比测量同位素比测量的灵敏度,准确性和精度,同时保持其简单性。检测到的PU +计数的平均数量较大180%,并且在使用纤维载荷时,比率测量的标准偏差减少了72%。当纤维载荷与珠子加载时的偏差为0.0028(0.284%)时,测量来自NBL CRM PU128的认证同位素比值的平均偏差。本研究中呈现的纤维形成方法可以扩展到其他阴离子交换聚合物化学物质,因此提供了一种方便的平台,以研究新型聚合物化学品在样品载荷中的效果。

著录项

  • 来源
    《Analytical chemistry》 |2017年第17期|共5页
  • 作者单位

    Clemson Univ Dept Chem &

    Biomol Engn 127 Earle Hall Clemson SC 29634 USA;

    Natl Secur Directorate Savannah River Natl Lab Aiken SC 29808 USA;

    Natl Secur Directorate Savannah River Natl Lab Aiken SC 29808 USA;

    Clemson Univ Dept Environm Engn &

    Earth Sci 342 Comp Court Anderson SC 29625 USA;

    Clemson Univ Dept Chem &

    Biomol Engn 127 Earle Hall Clemson SC 29634 USA;

  • 收录信息
  • 原文格式 PDF
  • 正文语种 eng
  • 中图分类 分析化学;
  • 关键词

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号