A comprehensive study was developed showing the feasibility of determination of rare earth elements (REE) in low concentration in crude oil by using direct sampling electrothermal vaporization system coupled to inductively coupled plasma mass spectrometry (ETV-ICP-MS). The effect of organic modifier on the REE signal was evaluated and the use of 6 mg of citric acid allowed calibration using aqueous reference solutions (selected pyrolysis and vaporization temperatures were 700 and 2200 degrees C, respectively). Because of the facility of REE in forming refractory compounds inside the graphite furnace during the heating step, the use of a modifier gas (Freon R-12, 3.0 mL min(-1)) was necessary to allow quantitative vaporization of these elements. A flow rate of 0.40 L min(-1) was selected for both bypass and carrier gases. Under optimized conditions, the influence of sample mass was evaluated, and even using a relatively high mass of crude oil (up to 18 mg), accurate results were obtained. The accuracy was evaluated by the comparison of results by ETV-ICP-MS with those obtained by ICP-MS with ultrasonic nebulizer (USN) after high-pressure microwave-assisted wet digestion (MAWD) and microwave-induced combustion (MIC) and no statistical difference was observed between the results. The limits of quantification for REE by ETV-ICP-MS were lower (0.02-0.8 ng g(-1)) than those obtained by USN-ICP-MS after MAWD and MIC (0.6-5.1 ng g(-1)). Negligible blank values and relative standard deviations lower than 12% show the feasibility of the proposed ETV-ICP-MS method for routine analysis of crude oil.
机译:通过使用耦合到电感耦合等离子体质谱(ETV-ICP-MS)的直接采样电热汽化系统,制定了综合研究表明了原油中低浓度的稀土元素(REE)的可行性。评价有机改性剂对REE信号的影响,并使用6mg使用含水参考溶液(选定的热解和蒸发温度分别为700和2200℃)。由于在加热步骤期间在石墨炉内形成耐火化合物的REE的设施,因此使用改性剂气体(氟康R-12,3.0mL min(-1))以允许定量蒸发这些元素。选择0.40 L min(-1)的流速,用于旁路和载气。在优化的条件下,评价样品质量的影响,甚至使用相对大量的原油(高达18mg),得到准确的结果。通过在高压微波辅助湿消解(MAWD)和微波诱导的燃烧(MIC)和NO在结果之间观察到统计学差异。 ETV-ICP-MS的REE的定量极限较低(0.02-0.8 ng(-1)),而MAWD和MIC之后通过USN-ICP-MS获得(0.6-5.1ng(-1))。忽略不计的空白值和低于12%的相对标准偏差显示了所提出的ETV-ICP-MS方法的可行性,用于原油的常规分析。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号