Intensity of extremely low-frequency electromagnetic fields produced in operating rooms during surgery at the standing position of anesthesiologists.

机译:在手术过程中麻醉师站立时在手术室中产生的极低频电磁场的强度。

获取原文
获取原文并翻译 | 示例
           

摘要

BACKGROUND: Numerous electronic devices have been introduced into operating rooms. Although little is known about the relationship between exposure to electromagnetic fields and health hazards, several studies have demonstrated causal relationships between electromagnetic fields exposure and various symptoms, cancers, and other diseases. METHODS: This study was approved by the Institutional Review Board. The intensity of extremely low-frequency electromagnetic fields was measured during surgery with the extremely low-frequency electromagnetic field strength measurement system at the standing position of anesthesiologists in 18 operating rooms and analyzed with EMDEX analysis and graphical program (EMCALC 95; ENERTECH, Campbell, CA). RESULTS: The average measurement duration per operating room per day was 7.41 +/- 0.70 h (mean +/- SD). The average sample number of measurements was 888.11 +/- 82.75 per operating room. The average magnetic field was 5.83 +/- 5.23 milliGuass (mG) (range, 0.10-33.80 mG), with 70% of these levels 2 mG or greater. CONCLUSIONS: The authors' results indicate that anesthesiologists in operating rooms are exposed to extremely low-frequency electromagnetic field levels that exceed magnetic field intensity of 2 mG recommended by the Swedish Board for Technical Accreditation for production by computer monitors and detected 30 cm from them. It currently is not clear if this exposure has health effects on anesthesiologists and other operating room personnel.
机译:背景技术:许多电子设备已经被引入手术室。尽管对电磁场暴露与健康危害之间的关系知之甚少,但一些研究表明电磁场暴露与各种症状,癌症和其他疾病之间存在因果关系。方法:本研究得到机构审查委员会的批准。极低频电磁场的强度是在手术过程中在18位手术室麻醉医师的站立位置使用极低频电磁场强度测量系统测量的,并通过EMDEX分析和图形程序进行分析(EMCALC 95; ENERTECH,Campbell, CA)。结果:每个手术室每天的平均测量时间为7.41 +/- 0.70 h(平均+/- SD)。每个手术室的平均测量样本数为888.11 +/- 82.75。平均磁场为5.83 +/- 5.23毫欧(mG)(范围为0.10-33.80 mG),其中70%的水平为2 mG或更大。结论:作者的结果表明,麻醉师在手术室中暴露于极低频电磁场中,该场强超过瑞典技术鉴定委员会推荐的由计算机显示器生产的2 mG磁场强度,并被发现距显示器30厘米。目前尚不清楚这种接触是否会对麻醉师和其他手术室人员产生健康影响。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号