首页> 外文期刊>Anesthesia and Analgesia: Journal of the International Anesthesia Research Society >A Feasibility Study Using the VivaSight Single Lumen? to Intubate the Trachea Through the Fastrach Laryngeal Mask Airway: A Preliminary Report of 50 Cases.
【24h】

A Feasibility Study Using the VivaSight Single Lumen? to Intubate the Trachea Through the Fastrach Laryngeal Mask Airway: A Preliminary Report of 50 Cases.

机译:使用VivaSight单流明的可行性研究?经法拉赫喉罩气管插管气管:50例初步报告。

获取原文
获取原文并翻译 | 示例
           

摘要

The VivaSight Single Lumen? (SL) is new endotracheal tube with a video camera and a light source in the tip allowing continuous visual observation of the airway. In this study, we checked the feasibility of endotracheal intubation with a VivaSight-SL through the Fastrach Laryngeal Mask Airway(?) (FT-LMA).We studied 50 patients with normal airways, scheduled for elective surgery during general anesthesia requiring endotracheal intubation. The FT-LMA was inserted and once adequate ventilation was achieved, the VivaSight-SL was passed through the FT-LMA into the trachea under visual control. The following criteria were used to score the laryngeal view: grade 1: full view of the arytenoids and glottis; grade 2: epiglottis, arytenoids or glottic opening are partly visible, the structure of cords is difficult to see; grade 3: dark areas indicating an open space; and grade 4: no part of the larynx can be identified.The FT-LMA was placed successfully in 49 patients at the first attempt. One patient was excluded from the study after 2 failed attempts to ventilate with the FT-LMA. All 49 patients were successfully intubated with the VivaSight-SL, (95% confidence interval [CI] 0.89-0.99), 47 patients at the first attempt (95% CI, 0.83-0.98) and 2 patients at the second attempt. (95% CI, 0.004-0.13). The time to achieve an effective airway with the FT-LMA was 15.4 ± 6 (mean ± SD) seconds. The time to achieve a laryngeal view with the VivaSight-SL was 28.8 ± 5 seconds. Correct position of the VivaSight-SL was confirmed with visualization of the carina. Time of successful intubation with VivaSight-SL from picking up the VivaSight-SL to observing a end-tidal CO(2) curve was 45 ± 7 seconds. After introducing the VivaSight-SL through the intubating channel of the FT-LMA, a grade 1 view was obtained in 18 patients, grade 2 in 18 patients, a grade 3 in 4 patients, and grade 4 in 9 patients.The high first-attempt intubation success rate using the VivaSight-SL to intubate the trachea through a FT-LMA makes this technique an attractive and promising concept.
机译:VivaSight单流明? (SL)是一种新型气管导管,尖端配有摄像机和光源,可以连续目视观察气道。在这项研究中,我们检查了通过Fastrach喉罩气道(?)(FT)进行VivaSight-SL气管插管的可行性。我们研究了50例正常气道的患者,计划在需要进行气管插管的全身麻醉期间进行择期手术。插入FT-LMA,一旦获得足够的通风,VivaSight-SL在可见的控制下通过FT-LMA进入气管。下列标准用于对喉镜评分:1级:ten和声门全貌; 2级:会厌、,突或声门开口部分可见,很难看到索的结构; 3级:表示开放空间的黑暗区域;以及4级:无法辨认出喉部。首次尝试将FT-LMA成功放置在49例患者中。在两次使用FT-LMA进行通气尝试失败后,将一名患者从研究中排除。所有49例患者均成功插管VivaSight-SL(95%置信区间[CI] 0.89-0.99),第一次尝试47例(95%CI,0.83-0.98)和第二次尝试2例。 (95%CI,0.004-0.13)。使用FT-LMA达到有效气道的时间为15.4±6(平均±SD)秒。使用VivaSight-SL进行喉镜检查所需的时间为28.8±5秒。通过隆起的可视化确认了VivaSight-SL的正确位置。从拿起VivaSight-SL到观察潮气末CO(2)曲线,用VivaSight-SL成功插管的时间为45±7秒。通过FT-LMA的插管通道引入VivaSight-SL后,在18例患者中获得1级视点,在18例患者中获得2级视点,在4例患者中获得3级视力,在9例患者中获得4级视力。尝试通过FT-LMA使用VivaSight-SL进行气管插管的成功率使该技术成为一种有吸引力且有希望的概念。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号