...
首页> 外文期刊>Andrology >The measurement properties of the five-item International Index of Erectile Function (IIEF-5): a Dutch validation study
【24h】

The measurement properties of the five-item International Index of Erectile Function (IIEF-5): a Dutch validation study

机译:五项国际勃起功能指数(IIEF-5)的测量特性:荷兰验证研究

获取原文
获取原文并翻译 | 示例
           

摘要

Erectile dysfunction (ED), affecting men worldwide, is associated with worse mental health. The severity of ED as well as the effect of its treatment can be assessed using valid self-reported outcome measures. A widely used measure is the International Index of Erectile Function short form (IIEF-5) which is not yet validated in Dutch. The objective of this study was to translate the IIEF-5 into Dutch and to investigate its reliability and validity to provide a useful evaluation tool. The IIEF-5 was translated into Dutch following standardized forward-backward procedures. To conduct this observational study, men with symptoms of ED completed the Dutch IIEF-5 at inclusion, 1 week later, and 6 months after inclusion. A population-based sample (reference group) completed the IIEF-5 once. The quality domains reliability and validity were addressed by testing the measurement properties internal consistency, reliability, measurement error, and content validity. Data of 82 patients and 253 reference group participants were analyzed. Internal consistency was adequate with Cronbach's alpha of 0.94 in both patient and reference group. In patients, the test-retest reliability was adequate with an intra-class correlation coefficient for agreement of 0.88. A floor effect was present in the patient group (42%), though not in the reference group (3%). There was no ceiling effect in patients (0%), while this was present in the reference group (17%). Analysis of responsiveness was not possible due to the limited number of patients receiving treatment. The Dutch IIEF-5 is a reliable and valid measure to determine severity of symptoms of ED. This evaluation tool is valuable for clinical use and interpreting results across international clinical studies. The context of a patient's sexual life is, however, indispensable and should be taken into account.
机译:勃起功能障碍(ED)影响世界各地的男性,其心理健康状况也较差。 ED的严重程度及其治疗效果可以使用有效的自我报告结果评估。广泛使用的一种措施是国际勃起功能指数缩写(IIEF-5),该形式尚未得到荷兰语的验证。这项研究的目的是将IIEF-5翻译成荷兰语,并研究其可靠性和有效性,以提供有用的评估工具。 IIEF-5按照标准的前进-后退程序翻译成荷兰语。为了进行这项观察性研究,有ED症状的男性在入院时,入院后1周和入院后6个月完成了Dutch IIEF-5。基于人群的样本(参考组)一次完成了IIEF-5。通过测试测量属性的内部一致性,可靠性,测量误差和内容有效性来解决质量域的可靠性和有效性。分析了82名患者和253名参考组参与者的数据。患者和参考组的内部一致性均达到0.94的Cronbach's alpha。在患者中,重测信度足够,组内相关系数为0.88。患者组(42%)有明显的反应,而参考组(3%)没有。患者无上限效应(0%),而参考组中有上限效应(17%)。由于接受治疗的患者数量有限,无法进行反应性分析。荷兰IIEF-5是确定ED症状严重程度的可靠有效方法。该评估工具对于临床使用和解释国际临床研究的结果非常有价值。但是,患者性生活的背景是必不可少的,应予以考虑。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号