首页> 外文期刊>Biomedical Chromatography: An International Journal Devoted to Research in Chromatographic Methodologies and Their Applications in the Biosciences >Monitoring of 8-oxo-7,8-dihydro-2'-deoxyguanosine in urine by high-performance liquid chromatography after pre-column derivatization with glyoxal reagents.
【24h】

Monitoring of 8-oxo-7,8-dihydro-2'-deoxyguanosine in urine by high-performance liquid chromatography after pre-column derivatization with glyoxal reagents.

机译:乙二醛试剂柱预衍生后,通过高效液相色谱法监测尿液中的8-氧代7,8-二氢-2'-脱氧鸟苷。

获取原文
获取原文并翻译 | 示例
获取外文期刊封面目录资料

摘要

A new, simple and sensitive pre-column fluorescence derivatization high-performance liquid chromatographic method for the determination of the oxidative DNA stress marker, 8-oxo-7,8-dihydro-2'-deoxyguanosine, was developed. Solid-phase extraction using an Oasis HLB cartridge avoided troublesome sample preparation steps, interference from charged species and frequent and essential electrode maintenance in electrochemical procedures. 8-Oxo-7,8-dihydro-2'-deoxyguanosine and other guanine compounds were selectively derivatized with glyoxal reagents (phenylglyoxal, 3,4-methylenedioxyglyoxal, 2-naphtylglyoxal and 6-methoxynaphthylglyoxal) at 40-60 degrees C. Derivatization with 6-methoxynaphthylglyoxal at 40 degrees C for 30 min gave the strongest fluorescence product. The fluorescence derivatives from reaction with 6-methoxynaphthylglyoxal were separated on a Capcell Pak C18 SG 120A column (4.6 mm i.d. x 150 mm, 5 microm) with acetonitrile-5 mM phosphate buffer (pH 6.0; 3:7, v/v) as mobile phase. The detection wavelength of the fluorescence derivative of 8-oxo-7,8-dihydro-2'-deoxyguanosine was lambda(ex) 400 nm and lambda(em) 510 nm. The detection limit of 8-oxo-7,8-dihydro-2'-deoxyguanosine was 1 ng/mL using 50 mL of urine. The calibration graphs were linear up to 30 microg/mL for 8-oxo-7,8-dihydro-2'-deoxyguanosine. The relative standard deviation of 20 ng/mL of 8-oxo-7,8-dihydro-2'-deoxyguanosine was 7.0%. The proposed method was compared with the enzymatic ELISA 8-oxo-7,8-dihydro-2'-deoxyguanosine analysis method (8-OH-dG Check, JaICA, Shizuoka, Japan). The correlation coefficient was 0.79 (n = 20) and y = 0.85x + 5.34. The proposed method was applied to the monitoring of 8-oxo-7,8-dihydro-2'-deoxyguanosine in urine from male heavy smokers.
机译:建立了一种新的,简便,灵敏的柱前荧光衍生高效液相色谱法,用于测定氧化性DNA胁迫标记物8-oxo-7,8-dihydro-2'-deoxyguanosine。使用Oasis HLB柱进行固相萃取,避免了麻烦的样品制备步骤,来自带电物质的干扰以及电化学程序中频繁且必要的电极维护。用乙二醛试剂(苯乙二醛,3,4-亚甲基二氧乙二醛,2-萘乙二醛和6-甲氧基萘乙二醛)在40-60°C下选择性衍生化8-Oxo-7,8-dihydro-2'-deoxyguanosine和其他鸟嘌呤化合物。在40摄氏度下30分钟,6-甲氧基萘乙二醛产生最强的荧光产物。与6-甲氧基萘乙二醛反应的荧光衍生物在Capcell Pak C18 SG 120A色谱柱(4.6 mm id x 150 mm,5 microm)上用乙腈-5 mM磷酸盐缓冲液(pH 6.0; 3:7,v / v)分离流动相。 8-oxo-7,8-dihydro-2'-deoxyguanosine的荧光衍生物的检测波长为λ(ex)400 nm和λ(em)510 nm。使用50 mL尿液,8-oxo-7,8-dihydro-2'-deoxyguanosine的检出限为1 ng / mL。对于8-oxo-7,8-dihydro-2'-deoxyguanosine,校准曲线呈线性,线性最高为30 microg / mL。 20 ng / mL的8-oxo-7,8-dihydro-2'-deoxyguanosine的相对标准偏差为7.0%。将该方法与酶联ELISA 8-oxo-7,8-dihydro-2'-deoxyguanosine分析方法(8-OH-dG Check,JaICA,静冈,日本)进行了比较。相关系数为0.79(n = 20),y = 0.85x + 5.34。该方法被用于监测男性大量吸烟者尿液中的8-氧代-7,8-二氢-2'-脱氧鸟苷。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号