Recently used wire EDM machines generate a triangular high peak discharge current of 500 ampere or more. It is very difficult to detect the true discharge voltage, because the discharge voltage is transformed by the influence of the high discharge current and impedance of the wire. In this study, we investigate the variation of discharge location and the discharge voltage immediately before the wire breakage in the case of high discharge current on wire EDM, in order to predict the wire breakage. Three methods that compensate the detected discharge voltage are proposed and the investigated results using these methods are described. It was found that in the case of low discharge current, phenomena immediately before the wire breakage such as local concentration of discharges and increase of short circuits in the gap, are clearly observed, but is difficult to observe them in the case of high discharge current.
机译:最近使用的电线EDM机器产生500安培或更高的三角形高峰放电电流。 非常难以检测真正的放电电压,因为通过电线的高放电电流和阻抗的影响变换了放电电压。 在这项研究中,我们在电线EDM上高放电电流的情况下,在线破损之前立即调查放电位置和放电电压的变化,以预测断线。 提出了三种补偿检测到的放电电压的方法,并描述了使用这些方法的研究结果。 发现,在低放电电流的情况下,清楚地观察到在电线断裂之前的局部放电浓度和间隙中短路的增加的情况下,难以在高放电电流的情况下观察它们 。