...
首页> 外文期刊>BioMed research international >Reliability of a Simple Physical Therapist Screening Tool to Assess Errors during Resistance Exercises for Musculoskeletal Pain
【24h】

Reliability of a Simple Physical Therapist Screening Tool to Assess Errors during Resistance Exercises for Musculoskeletal Pain

机译:一个简单的物理治疗师筛选工具来评估肌肉骨骼疼痛的抵抗运动中的错误的可靠性

获取原文
获取原文并翻译 | 示例
           

摘要

The main objective was to investigate the intra- and intertester reliability of a simple screening tool assessing errors in exercise execution by visual observation. 38 participants with no previous resistance exercise experience practiced for two weeks four typical upper limb exercises using elastic tubing. At 2-week follow-up, the participants were invited for a test-retest assessment on errors in technical execution. The assessment was based on ordinal deviation of joint position from neutral of the shoulder, elbow, and wrist in a single plane by visual observation. Moderate intratester reliability weighted kappa (wK) score ranging from 0.50 (0.21-0.71) to 0.57 (0.24-0.82) for observer 1 and a fair to moderate intratester reliability wK score ranging from 0.27 (0.09-0.43) to 0.52 (0.15-0.86) for observer 2 across the four exercises was observed. For intertester reliability moderate to substantial mean wK scores were found between the two observers, slightly improving from round one to round two ranging from 0.40 (0.20-0.59) to 0.68 (0.45-0.91) in round one to 0.52 (0.20-0.80) to 0.69 (0.39-0.86) in round two. The exercise error assessment demonstrated fair to substantial intratester and intertester reliability, which is congruent with previously published studies. Hence the simplicity of defining a neutral joint position for each of the involved joints in the exercise and categorizing the deviation in "some deviation" and "substantial deviation" to either side in a single plane is a viable and inexpensive solution when assessing for errors during exercise.
机译:主要目的是研究通过视觉观察评估运动执行中错误的简单筛选工具的测试者内部和测试者之间的可靠性。 38名以前没有阻力锻炼经验的参与者使用弹性管练习了两个星期,进行了四个典型的上肢锻炼。在2周的随访中,邀请参与者对技术执行中的错误进行重新测试评估。该评估是基于目视观察在单个平面中关节位置相对于肩膀,肘部和腕部中立点的顺序偏差。观察者1的中等测试者内部可靠性加权kappa(wK)得分范围从0.50(0.21-0.71)到0.57(0.24-0.82),中等到中等的测试者内部可靠性wK得分范围从0.27(0.09-0.43)到0.52(0.15-0.86) ),观察者2在四个练习中均被观察到。对于测试者间的可靠性,在两个观察者之间发现了中等到较高的平均wK得分,从第一轮到第二轮略有提高,从第一轮的0.40(0.20-0.59)到0.68(0.45-0.91)到0.52(0.20-0.80)到第二轮为0.69(0.39-0.86)。运动误差评估显示出相当高的测试者内部和测试者之间的可靠性,这与先前发表的研究一致。因此,在评估运动中的错误时,为练习中每个所涉及的关节定义一个中立的关节位置并在单个平面中将“某些偏离”和“实质性偏离”的偏差分类到任一侧的简单性是一种可行且廉价的解决方案行使。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号