首页> 外文期刊>Biomedical Chromatography: An International Journal Devoted to Research in Chromatographic Methodologies and Their Applications in the Biosciences >An HPLC method with diode array detector for the simultaneous quantification of chloroquine and desethylchloroquine in plasma and whole blood samples from Plasmodium vivax patients in Vietnam, using quinine as an internal standard
【24h】

An HPLC method with diode array detector for the simultaneous quantification of chloroquine and desethylchloroquine in plasma and whole blood samples from Plasmodium vivax patients in Vietnam, using quinine as an internal standard

机译:带有二极管阵列检测器的HPLC方法,以奎宁为内标,同时定量分析越南间日疟原虫患者血浆和全血样品中的氯喹和去乙基氯喹

获取原文
获取原文并翻译 | 示例
           

摘要

A sensitive, simple method for quantification of chloroquine (CQ) and desethylchloroquine (MCQ) in whole blood and plasma from Plasmodium vivax patients has been developed using HPLC with diode array detection (DAD). Solid-phase extraction on Isolute-96-CBA was employed to process 100L of plasma/whole blood samples. CQ, MCQ and quinine were separated using a mobile phase of phosphate buffer 25mm, pH2.60-acetonitrile (88:12, v/v) with 2mm sodium perchlorate on a Zorbax SB-CN 150x4.6mm, 5m column at a flow rate of 1.2mL/min, at ambient temperature in 10min, with the DAD wavelength of 343nm. The method was linear over the range of 10-5000ng/mL for both CQ and MCQ in plasma and whole blood. The limit of detection was 4ng/mL and limit of quantification was 10ng/mL in both plasma and blood for CQ and MCQ. The intra-, inter- and total assay precision were <10% for CQ and MCQ in plasma and whole blood. In plasma, the accuracies varied between 101 and 103%, whereas in whole blood, the accuracies ranged from 97.0 to 102% for CQ and MCQ. The method is an ideal technique with simple facilities and instruments, bringing about good separation in comparison with previous methods. (c) 2016 The Authors Biomedical Chromatography Published by John Wiley & Sons Ltd
机译:使用带有二极管阵列检测(DAD)的HPLC开发了一种灵敏,简单的定量间日疟原虫患者全血和血浆中氯喹(CQ)和去乙基氯喹(MCQ)的方法。在Isolute-96-CBA上进行固相萃取可处理100L血浆/全血样品。在Zorbax SB-CN 150x4.6mm,5m色谱柱上,使用磷酸盐缓冲液25mm,pH2.60-乙腈(88:12,v / v)和2mm高氯酸钠的流动相在流动相上分离CQ,MCQ和奎宁在室温下10分钟内测得1.2mL / min的DAD波长为343nm。对于血浆和全血中的CQ和MCQ,该方法在10-5000ng / mL范围内是线性的。 CQ和MCQ在血浆和血液中的检出限为4ng / mL,定量限为10ng / mL。血浆和全血中CQ和MCQ的内部,内部和总测定精度均<10%。在血浆中,准确度在101%至103%之间变化,而在全血中,CQ和MCQ的准确度在97.0%至102%之间。该方法是具有简单设备和仪器的理想技术,与以前的方法相比具有良好的分离效果。 (c)2016年作者生物医学色谱法,约翰·威利父子有限公司出版

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号