首页> 外文期刊>Biomedical Chromatography: An International Journal Devoted to Research in Chromatographic Methodologies and Their Applications in the Biosciences >Determination of cefuroxime lysine in rat brain microdialysates by ultra-fast liquid chromatography with UV and tandem mass spectrometry: application to an acute toxicokinetic study
【24h】

Determination of cefuroxime lysine in rat brain microdialysates by ultra-fast liquid chromatography with UV and tandem mass spectrometry: application to an acute toxicokinetic study

机译:紫外和串联质谱超快速液相色谱法测定大鼠脑微量透析液中的头孢呋辛赖氨酸:在急性毒物动力学研究中的应用

获取原文
获取原文并翻译 | 示例
           

摘要

Cefuroxime lysine is a new second-generation cephalosporins, which can penetrate the blood-brain barrier to cure the meningitis. In order to investigate its acute toxicokinetic study after intraperitoneal injection of 675 mg/kg cefuroxime lysine, a sensitive and clean ultra-fast liquid chromatography-tandem mass spectrometry (UFLC-MS/MS) method for the determination of cefuroxime lysine in microdialysate samples was developed and validated, which was compared with UFLC-UV as a reference method. Chromatographic separation was performed on a Shim-pack XR-ODS C-18 column (75 x 3.0 mm, 2.2 mu m), with an isocratic elution of 0.1% formic acid in acetonitrile-0.1% formic acid in water (45:55, v/v) for LC-MS and acetonitrile-20mM potassium dihydrogen phosphate (pH 3.0,20:80, v/v) for LC-UV. The lower limit of detection was 0.01 mu g/mL for LC-MS and 0.1 mu g/mL for LC-UV method, with the same corresponding linearity range of 0.1-50 mu g/mL. The intra-and inter-day precisions (relative standard deviation) for both methods were from 1.1 to 8.9%, while the accuracy was all within +/- 10.9%. The results of both methods were finally compared using paired t-test; the results indicated that the concentrations measured by the two methods correlated significantly (p < 0.05), which suggested that the two methods based on LC-MS and LC-UV were suitable for the acute toxicokinetic study. Copyright (C) 2014 John Wiley & Sons, Ltd.
机译:头孢呋辛赖氨酸是一种新型的第二代头孢菌素,它可以穿透血脑屏障来治愈脑膜炎。为了研究腹膜内注射675 mg / kg头孢呋辛肟赖氨酸后的急性毒物动力学研究,采用灵敏,清洁的超快液相色谱-串联质谱法(UFLC-MS / MS)测定微量透析液中的头孢呋辛赖氨酸。开发并验证,并将其与UFLC-UV作为参考方法进行比较。色谱分离是在Shim-pack XR-ODS C-18色谱柱(75 x 3.0 mm,2.2μm)上进行的,等度洗脱为0.1%的甲酸在乙腈中的溶液-0.1%的甲酸在水中的溶液(45:55, LC / MS)和乙腈20mM磷酸二氢钾(pH 3.0,20:80,v / v)用于LC-UV。 LC-MS的检测下限为0.01μg / mL,LC-UV方法的检测下限为0.1μg / mL,相同的线性范围为0.1-50μg / mL。两种方法的日内和日间精度(相对标准偏差)为1.1%至8.9%,而所有精度均在+/- 10.9%之内。最后,使用配对t检验比较了两种方法的结果。结果表明,两种方法测得的浓度显着相关(p <0.05),这表明基于LC-MS和LC-UV的两种方法均适用于急性毒物动力学研究。版权所有(C)2014 John Wiley&Sons,Ltd.

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号