INTRODUCTION: The purpose of this study was to compare galvanic currents generated by different combinations of commonly used brackets and archwires. METHODS: As-received stainless steel, nickel-titanium, and beta-titanium wires were coupled to stainless steel and titanium brackets in an artificial saliva medium. The galvanic current and amount of charge transferred for each pair were monitored with a zero resistance ammeter for 10 hours. RESULTS: Two-way analysis of variance (ANOVA) showed a significant difference in charge and galvanic currents when factored for type of bracket (P <0.001), but no significant difference between them when factored by type of wire (P >0.05). Specifically, a brazed stainless steel bracket was significantly greater in charge transferred and 10-hour galvanic current than metal injection molded stainless steel and titanium brackets (P <0.001), which were not different from each other (P >0.05). CONCLUSIONS: The method of bracket manufacturing might be of equal or more relevance to galvanic corrosion susceptibility than bracket composition.
机译:引言:本研究的目的是比较由常用托槽和弓丝的不同组合产生的电流。方法:在人造唾液介质中,将接收到的不锈钢,镍钛和β钛丝与不锈钢和钛支架连接。用零电阻电流表监测每对电流电流和电荷转移量10小时。结果:双向方差分析(ANOVA)显示,当考虑支架类型时,电荷电流和电流电流存在显着差异(P <0.001),但是当根据导线类型进行分析时,两者之间无显着差异(P> 0.05)。具体而言,与金属注射成型的不锈钢和钛制支架相比,钎焊不锈钢支架在电荷转移和10小时电流电流方面显着更大(P <0.001),两者之间没有差异(P> 0.05)。结论:支架的制造方法与电蚀敏感性比支架组成具有更高的相关性。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号