首页> 外文期刊>エバラ時報 >Vibration analysis on large-scale drainage pumping station
【24h】

Vibration analysis on large-scale drainage pumping station

机译:大型排水泵站的振动分析

获取原文
获取原文并翻译 | 示例
           

摘要

An FEM model was established for analyzing the vibratory propagation characteristics of large scale pumping stations, whose structures arc in the majority of cases made of concrete. Vibration analysis of a station, which was 98 meters in length.)meters in width and 34 meters in height, was carried out in a frequency range of 0-100 Hz. Analysis results were compared with those of measurements and they showed good agreement. Furthermore, factors affecting the accuracy of analysis were investigatedand the results are as the following : (1) Vibration responses at locations nearby the excitation source could be estimated by analyzing neighboring portions of the structure, (2) Spring constants of thc ground had influence only on a low frequency range, and (3) Damping ratios were frequency dependent, having great influence on responses at locations away from the excitation source.
机译:建立了一个有限元模型,用于分析大规模泵站的振动传播特性,其结构弧在混凝土大多数情况下。 车站的振动分析,长度为98米。)宽度和34米的高度,在0-100Hz的频率范围内进行。 将分析结果与测量结果进行比较,他们表现出良好的一致性。 此外,研究了影响分析准确性的因素和结果如下:(1)通过分析结构的相邻部分,可以估计激励源附近的位置处的振动响应,(2)THC地面的弹簧常数仅有影响 在低频范围内,(3)阻尼比率是频率依赖性,对远离激发源的位置的反应产生很大影响。