INTRODUCTION: When mini-implants fail during orthodontic treatment, there is a need to have a backup plan to either replace the failed implant in the adjacent interradicular area or wait for the bone to heal before replacing the mini-implant. We propose a novel way to overcome this problem by replacement with a miniplate so as not to interrupt treatment or prolong treatment time. METHODS: The indications, advantages, efficacy, and procedures for switching from a mini-implant to a miniplate are discussed. Two patients who required replacement of failed mini-implants are presented. In the first patient, because of the proximity of the buccal vestibule to the mini-implant, it was decided to replace the failed mini-implant by an I-shaped C-tube miniplate. In the second patient, radiolucencies were found around the failed mini-implants, making the adjacent alveolar bone unavailable for immediate placement of another mini-implant. In addition, the maxillary sinus pneumatization was expanded deeply into the interradicular spaces; this further mandated an alternative placement site. One failed mini-implant was examined under a scanning electron microscope for bone attachment. RESULTS: Treatment was completed in both patients after replacement with miniplates without interrupting the treatment mechanics or prolonging the treatments. Examination under the scanning electron microscope showed partial bone growth into the coating pores and titanium substrate interface even after thorough cleaning and sterilization. CONCLUSIONS: Replacement with a miniplate is a viable solution for failed mini-implants during orthodontic treatment. The results from microscopic evaluation of the failed mini-implant suggest that stringent guidelines are needed for recycling used mini-implants.
机译:简介:当正畸治疗期间微型植入物失效时,有必要制定备用计划,以在相邻的小梁间区域内更换失效的植入物,或者等待骨头愈合后再更换微型植入物。我们提出了一种新颖的方法来解决此问题,方法是用小板替代,以免中断治疗或延长治疗时间。方法:讨论了从微型植入物转换为微型板的适应症,优点,功效和程序。介绍了两名需要更换失败的微型植入物的患者。在第一例患者中,由于颊前庭接近微型植入物,因此决定用I形C型管微型平板代替失败的微型植入物。在第二例患者中,在失败的微型植入物周围发现了放射线透亮性,使得相邻的牙槽骨无法立即放置另一个微型植入物。此外,上颌窦气化深深地扩展到了放射间隙。这进一步规定了替代安置地点。在扫描电子显微镜下检查了一个失败的微型植入物的骨附着情况。结果:更换小板后,两名患者均完成了治疗,而没有中断治疗机制或延长治疗时间。在扫描电子显微镜下的检查显示,即使经过彻底的清洁和消毒,骨头仍会部分进入涂层孔和钛基底界面。结论:用微孔板替代是治疗正畸治疗中失败的微型植入物的可行解决方案。对失败的微型植入物进行微观评估的结果表明,需要严格的准则来回收用过的微型植入物。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号