Austenitic stainless steel (German and USA (AISI) designations (X2CrNiMo18-14-3 and 316L respectively) was studied in stress controlled tests on the high cycle fatigue (HCF) regime in air at room temperature. Stress-strain responses were carefully measured to clarify the stress amplitude dependent fatigue behavior of this steel. The fatigue tests were performed at constant-amplitude cyclic loading with load ratio of R=-l The results showed that the fatigue limit of AISI 316L stainless steel at room temperature was 190-200 MPa.
机译:研究了奥氏体不锈钢(德国和美国(AISI)标准(分别为X2Crnimo18-14-3和316L),在室温下的高循环疲劳(HCF)制度上的应力控制测试中研究。仔细测量应力 - 应变响应 阐明该钢的应力幅度依赖性疲劳行为。疲劳试验在恒定振幅负载下进行R = -L的负载比进行结果表明,结果表明,室温下AISI 316L不锈钢的疲劳极限为190-200MPa 。