首页> 外文期刊>American Journal of Ophthalmology: The International Journal of Ophthalmology >Ocular and optical coherence tomography-based corneal aberrometry in keratoconic eyes treated by intracorneal ring segments
【24h】

Ocular and optical coherence tomography-based corneal aberrometry in keratoconic eyes treated by intracorneal ring segments

机译:角膜内环段治疗角膜圆锥形眼中基于光学和光学相干层析成像的角膜像差法

获取原文
获取原文并翻译 | 示例
           

摘要

Purpose To analyze corneal and total aberrations using custom-developed anterior segment spectral optical coherence tomography (OCT) and laser ray tracing in keratoconic eyes implanted with intracorneal ring segments (ICRS). Design Evaluation of technology. Prospective study. Case series. Methods Nineteen keratoconic eyes were measured before and after ICRS surgery. Anterior and posterior corneal topographic and pachymetric maps were obtained pre- and postoperatively from 3-dimensional OCT images of the anterior segment, following automatic image analysis and distortion correction. The pupil center coordinates were used as reference for estimation of corneal aberrations. Corneal aberrations were estimated by computational ray tracing on the anterior and posterior corneal surfaces. Total aberrations were measured using a custom-developed laser ray tracing aberrometer. Corneal and total aberrations were compared in 8 eyes pre- and postoperatively for 4-mm pupils. Results Total and corneal aberrations were highly correlated. Average root mean square of corneal and total high-order aberrations (HOAs) were 0.78 ± 0.35 μm and 0.57 ± 0.39 μm preoperatively, and 0.88 ± 0.36 μm and 0.53 ± 0.24 μm postoperatively (4-mm pupils). The anterior corneal surface aberrations were partially compensated by the posterior corneal surface aberrations (by 8.3% preoperatively and 4.1% postoperatively). Astigmatism was 2.03 ± 1.11 μm preoperatively and 1.60 ± 0.94 μm postoperatively. The dominant HOA aberrations both pre- and postoperatively were vertical coma (Z3 -1), vertical trefoil (Z 3 -3), and secondary astigmatism (Z4 4). ICRS decreased corneal astigmatism by 27% and corneal coma by 5%, but on average, the overall amount of HOA did not decrease significantly with ICRS treatment. Conclusions OCT is a reproducible technique to evaluate corneal aberrations. OCT-based corneal aberrations and ocular aberrations show a high correspondence in keratoconic patients before and after ICRS implantation. ICRS produced a decrease in astigmatism, but on average did not produce a consistent decrease of HOAs.
机译:目的使用定制开发的前段光谱光学相干断层扫描(OCT)和激光跟踪在植入了角膜内环段(ICRS)的圆锥角膜眼中分析角膜和总像差。技术设计评估。前瞻性研究。案例系列。方法在ICRS手术前后,对19只圆锥角膜眼睛进行测量。在自动图像分析和畸变校正之后,从前节的3维OCT图像获得术前和术后的角膜前和后角地形图和测厚图。将瞳孔中心坐标用作估计角膜像差的参考。通过在角膜前表面和后表面上的计算机射线追踪估计角膜像差。总像差是使用定制开发的激光跟踪像差仪测量的。比较了4-mm瞳孔术前和术后8只眼的角膜和总像差。结果总和角膜像差高度相关。术前角膜和总高阶像差(HOA)的平均均方根值分别为0.78±0.35μm和0.57±0.39μm,术后(0.8 mm±4 mm)分别为0.88±0.36μm和0.53±0.24μm。角膜前表面畸变部分地被角膜后表面畸变所补偿(术前为8.3%,术后为4.1%)。术前散光为2.03±1.11μm,术后散光为1.60±0.94μm。术前和术后主要的HOA像差为垂直昏迷(Z3 -1),垂直三叶形(Z 3 -3)和继发散光(Z4 4)。 ICRS使角膜散光减少27%,角膜昏迷减少5%,但平均而言,使用ICRS治疗后,HOA的总量并未显着减少。结论OCT是一种可重现的技术,可评估角膜像差。基于OCT的角膜畸变和眼部畸变在圆锥角膜病患者植入ICRS之前和之后显示出很高的对应性。 ICRS减少了散光,但平均而言并没有使HOA持续减少。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号