OBJECTIVE: To compare results reported for blood gas partial pressures, electrolyte concentrations, and Hct in venous blood samples collected from cattle, horses, and sheep and analyzed by use of a portable clinical analyzer (PCA) and reference analyzer (RA). ANIMALS: Clinically normal animals (24 cattle, 22 horses, and 22 sheep). PROCEDURES: pH; Pco(2); Po(2); total carbon dioxide concentration; oxygen saturation; base excess; concentrations of HCO(3)(-), Na(+), K(+), and ionized calcium; Hct; and hemoglobin concentration were determined with a PCA. Results were compared with those obtained for the same blood sample with an RA. Bias (mean difference) and variability (95% confidence interval) were determined for all data reported. Data were also subjected to analyses by Deming regression and Pearson correlation. RESULTS: Analysis of Bland-Altman plots revealed good agreement between results obtained with the PCA and those obtained with the RA for pH and total carbon dioxide concentration in cattle, K(+) concentration in horses and sheep, and base excess in horses. Except for Na(+) concentration and Hct in horses and sheep, correlation was good or excellent for most variables reported. CONCLUSIONS AND CLINICAL RELEVANCE: Data from blood gas and electrolyte analyses obtained by use of the PCA can be used to evaluate the health status of cattle, horses, and sheep. Furthermore, the handheld PCA device may have a great advantage over the RA device as a result of the ability to analyze blood samples on farms that may be located far from urban centers.
机译:目的:比较从牛,马和绵羊采集并通过便携式临床分析仪(PCA)和参考分析仪(RA)分析的静脉血样品中血气分压,电解质浓度和Hct的报告结果。动物:临床上正常的动物(24头牛,22匹马和22只绵羊)。程序:pH; Pco(2); Po(2);总二氧化碳浓度;氧饱和度基本过剩; HCO(3)(-),Na(+),K(+)和离子钙的浓度; Hct;用PCA测定血红蛋白浓度。将结果与使用RA的相同血样获得的结果进行比较。确定了报告的所有数据的偏差(均值差异)和变异性(95%置信区间)。还通过Deming回归和Pearson相关对数据进行了分析。结果:对Bland-Altman图的分析表明,用PCA和用RA获得的结果在牛的pH和总二氧化碳浓度,马和绵羊中的K(+)浓度以及马中的碱过量方面都具有良好的一致性。除了马和绵羊中的Na(+)浓度和Hct外,对于大多数报告的变量,相关性都很好。结论与临床意义:通过使用PCA获得的血气和电解质分析数据可用于评估牛,马和绵羊的健康状况。此外,由于能够分析可能远离城市中心的农场的血液样本,因此手持式PCA设备可能比RA设备具有更大的优势。

著录项

相似文献

  • 外文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号