Evaluation of two portable meters for determination of blood triglyceride concentration in dogs

机译:评估两个便携式血糖仪测定狗血甘油三酯浓度的方法

获取原文
获取原文并翻译 | 示例
   

获取外文期刊封面封底 >>

       

摘要

Objective-To evaluate agreement between 2 portable triglyceride meters and a veterinary laboratory for measurement of blood triglyceride concentrations in dogs and evaluate effects of Hct and blood volume analyzed.Sample Population-97 blood samples collected from 60 dogs.Procedures-Triglyceride concentrations were measured in blood by use of 2 meters and compared with serum triglyceride concentrations determined by a veterinary laboratory. Within- and between-day precision, accuracy, and effects of blood volume and Hct were analyzed.Results-Accuracy of both meters varied with triglyceride concentration, although both accurately delineated dogs with triglyceride concentrations < 180 mg/dL versus 180 mg/dL. One meter had results with excellent overall correlation with results of the standard laboratory method, with a concordance correlation coefficient of 0.94 and mean difference of 20.3 mg/dL. The other meter had a good overall concordance correlation coefficient of 0.86 with a higher absolute mean difference of -27.7 mg/dL. Results were only affected by blood volume; triglyceride concentrations determined via both meters were significantly lower when 7 mu L of EDTA-anticoagulated blood was used, compared with larger volumes.Conclusions and Clinical Relevance-1 meter had greater accuracy in the range of 140 to 400 mg/dL and was therefore well suited to detect hypertriglyceridemia. The other meter was accurate with triglyceride values < 140 mg/dL and yielded results similar to those of the veterinary laboratory in the range of 140 to 400 mg/dL, therefore being suitable for determination of triglyceride concentrations in nonfed dogs and dogs with mildly high concentrations. (Am J Vet Res 2010;71:203-2 10)
机译:目的-评估2台便携式甘油三酸酯仪与兽医实验室之间测量狗血中甘油三酸酯浓度的一致性,并评估Hct和血容量的影响。从60只狗中采集97个样本的样本。使用2米的血液,并与兽医实验室测定的血清甘油三酸酯浓度进行比较。分析了日间和日间精度,准确度以及血容量和Hct的影响。结果,两种仪表的准确度均随甘油三酯浓度的变化而变化,尽管两只狗的准确描绘都表明甘油三酯浓度<180 mg / dL与180 mg / dL。一米的结果与标准实验室方法的结果具有出色的总体相关性,一致性相关系数为0.94,平均差为20.3 mg / dL。另一台仪表的总体一致性相关系数为0.86,绝对平均差更高,为-27.7 mg / dL。结果仅受血容量影响;当使用7μL EDTA抗凝血液时,通过两个仪表测定的甘油三酸酯浓度均显着降低,而体积较大。结论和Clinical Relevance-1仪表在140至400 mg / dL范围内具有更高的准确度,因此很好适合检测高甘油三酸酯血症。另一台仪表的甘油三酯值<140 mg / dL准确,得出的结果与兽医实验室相似,在140至400 mg / dL范围内,因此适用于测定非喂养狗和轻度高狗的甘油三酯浓度浓度。 (Am J Vet Res 2010; 71:203-2 10)

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号