Background: Augmented reality (AR) surgical navigation systems, designed to increase accuracy and efficiency, have been shown to negatively impact on attention. We wished to assess the effect "head-up" AR displays have on attention, efficiency, and accuracy, while performing a surgical task, compared with the same information being presented on a submonitor (SM).Methods: Fifty experienced otolaryngology surgeons (n = 42) and senior otolaryngology trainees (n = 8) performed an endoscopic surgical navigation exercise on a predissected cadaveric model. Computed tomography-generated anatomic contours were fused with the endoscopic image to provide an AR view. Subjects were randomized to perform the task with a standard endoscopic monitor with the AR navigation displayed on an SM or with AR as a single display. Accuracy, task completion time, and the recognition of unexpected findings (a foreign body and a critical complication) were recorded.Results: Recognition of the foreign body was significantly better in the SM group (15/25 [60%]) compared with the AR alone group (8/25 [32%]; p = 0.02). There was no significant difference in task completion time (p = 0.83) or accuracy (p = 0.78) between the two groups.Conclusion: Providing identical surgical navigation on a SM, rather than on a single head-up display, reduced the level of inattentional blindness as measured by detection of unexpected findings. These gains were achieved without any measurable impact on efficiency or accuracy. AR displays may distract the user and we caution injudicious adoption of this technology for medical procedures.
机译:背景:旨在提高准确性和效率的增强现实(AR)手术导航系统已显示出对注意力的负面影响。我们希望评估“平视式” AR显示器在执行外科手术任务时,与子监视器(SM)上呈现的相同信息相比,对注意力,效率和准确性的影响。方法:五十名经验丰富的耳鼻喉科外科医生(n = 42)和高级耳鼻喉科受训人员(n = 8)对预先解剖的尸体模型进行了内窥镜手术导航练习。计算机断层扫描生成的解剖轮廓与内窥镜图像融合以提供AR视图。使用标准内窥镜监视器将受试者随机分组以执行任务,其中AR导航显示在SM上或AR作为单个显示器。记录准确性,任务完成时间和对意外发现(异物和严重并发症)的识别。结果:与SM组相比,SM组中异物的识别性更好(15/25 [60%])。仅AR组(8/25 [32%]; p = 0.02)。两组之间的任务完成时间(p = 0.83)或准确性(p = 0.78)均无显着差异。结论:在SM上而不是在一个平视显示器上提供相同的手术导航,可降低手术的水平。通过检测意外发现来衡量的注意力不集中失明。这些收益的实现对效率或准确性没有任何可衡量的影响。 AR显示器可能会分散用户的注意力,我们提醒您在医疗程序中误用此技术。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号