The molten carbonate fuel cell (MCFC) power plant has significant advantages such as high efficiency and low emissions of NO_x and SO_x, so commercialization is expected for power generation. A 1000 kW class MCFC power plant was constructed and tested by MCFC Research Association in Kawagoe Power Station of Chubu Electric Power Co., Inc. IHI supplied the MCFC Stack facility (500 kW), control system, and operation supervision for the plant test operation. Good operation controllability was confirmed. This paper reports the outline of the control system and operation test result.
机译:熔融的碳酸盐燃料电池(MCFC)发电厂具有显着的优点,例如NO_X和SO_X的高效率和低排放,因此预计发电的商业化。 由Chubu电力公司Kawagoe电站的MCFC研究协会构建和测试了1000千瓦级MCFC电厂,IHI提供了MCFC堆栈设施(500千瓦),控制系统和工厂测试操作的操作监督 。 确认了良好的操作可控性。 本文报告了控制系统的轮廓和操作测试结果。