A randomized single-blind controlled trial comparing two monochromatic near-infrared light devices: Implications for tissue heating and safety

机译:比较两个单色近红外光设备的随机单盲对照试验:对组织加热和安全性的影响

获取原文
获取原文并翻译 | 示例
           

摘要

OBJECTIVE: Use of near-infrared light (NIR) is becoming more commonplace in the treatment of different pathologies; however, its safety in terms of heat generation and penetration has not been documented. The purpose of this investigation was to determine and compare skin surface and underlying tissue temperature response during and for 15 mins after a 30-min NIR application to the posterior lower leg using two different NIR devices (Anodyne and HealthLight) and one sham treatment. With this information, recommendations regarding potential adverse skin reactions, including burns, can be made. In addition, these results can serve as a reference for further studies. DESIGN: This single-blind randomized controlled study used a repeated-measures design. Fifteen healthy college-age individuals randomly received 30-min treatments with two different near-infrared devices and one sham device to their lower leg. A thermistor underneath the diode and a thermocouple with temperature sensors at three depths measured the temperature at skin surface and in deep tissues, respectively, every minute during the treatment and for 15 mins posttreatment. RESULTS: After 30 mins of treatment, there was a significant temperature increase between the NIR devices underneath the diodes and all tissue depths and the control. The skin temperature underneath the treatment diodes increased about 9.5°C from baseline to 40°C. There was no difference between the tissue temperature changes in response to the irradiation with the two NIR heating devices. A limitation of the study is that the entire sample was drawn from a healthy college population. CONCLUSIONS: The surface and underlying tissue temperature heating produced by the two NIR devices is within limits considered safe for healthy subjects.
机译:目的:近红外光(NIR)在不同病理学中的治疗变得越来越普遍。但是,其在发热和渗透方面的安全性尚未得到证明。这项研究的目的是确定并比较使用两种不同的NIR设备(Anodyne和HealthLight)和一种假手术对小腿后部施行30分钟NIR期间和之后15分钟的皮肤表面和底层组织温度响应。有了这些信息,就可以对潜在的不良皮肤反应(包括烧伤)提出建议。此外,这些结果可作为进一步研究的参考。设计:该单盲随机对照研究采用重复测量设计。 15名健康的大学年龄个体在其小腿上随机接受了两种不同的近红外设备和一种假设备进行的30分钟治疗。二极管下方的热敏电阻和在三个深度带有温度传感器的热电偶分别在治疗过程中每分钟和治疗后15分钟分别测量皮肤表面和深层组织中的温度。结果:治疗30分钟后,二极管下方的NIR装置与所有组织深度和对照之间的温度均显着升高。治疗二极管下方的皮肤温度从基线升高到约40°C,约9.5°C。响应于两个NIR加热设备的照射,组织温度变化之间没有差异。该研究的局限性在于整个样本均来自健康的大学人群。结论:两个NIR设备产生的表面和下面的组织温度加热在认为对健康受试者安全的范围内。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号