Different systems consisting of a reagent and a fibrous adsorbent filled with an anion exchanger were studied in determining Molybdenum (VI) by solid-phase spectroscopy. A system of a fibrous adsorbent filled with an AV-17 anion exchanger and phenylfluorone was selected and studied. The system provides the determination of molybdenum with a detection limit of 0.002 mg/l in the presence of different cations that usually interfere with the determination. A procedure for determining molybdenum (RSD < 15%) was developed and verified in analyses of river, well, and tap water. The analysis takes 15-20 min.
机译:通过固相光谱法研究了由试剂和填充有阴离子交换剂的纤维吸附剂组成的不同系统。 选择并研究了填充有AV-17阴离子交换剂和苯基氟酮的纤维吸附剂的系统。 该系统在不同阳离子存在下,在通常干扰测定的不同阳离子存在下,该系统在不同阳离子的存在下测定钼的测定。 在河流,井和自来水分析中开发并验证了测定钼(RSD <15%)的方法。 分析需要15-20分钟。