首页> 外文期刊>Journal of orthodontics >In vivo evaluation of two new moisture-resistant orthodontic adhesive systems: a comparative clinical trial.
【24h】

In vivo evaluation of two new moisture-resistant orthodontic adhesive systems: a comparative clinical trial.

机译:体内评价两种新的耐湿状正畸粘合剂系统:比较临床试验。

获取原文
获取原文并翻译 | 示例
       

摘要

OBJECTIVE: To evaluate and compare the clinical performance of two new moisture-resistant orthodontic adhesive systems: a chemically-cured composite resin (Unite, 3M Unitek, Monrovia, California, USA) in conjunction with a special moisture-resistant primer (Transbond MIP, 3M Unitek, Monrovia, California, USA); and a fluoride-releasing light-cured compomer (Assure, Reliance Orthodontic Products, Inc., Itasca, Illinois, USA). DESIGN: Randomized controlled clinical trial using the 'split-mouth' technique. SETTING: Department of Orthodontics, Aristotle University of Thessaloniki. Subjects (Materials) and Methods: Twenty-five consecutively started patients (13 females and 12 males) requiring fixed appliance orthodontic treatment. INTERVENTIONS: Four-hundred-and-thirty-six stainless steel brackets bonded to all teeth except molars using two different moisture-resistant orthodontic adhesive systems. MAIN OUTCOME MEASURES: Bond failure rates during a period of 9 months were estimated for each adhesive system and the corresponding bracket survival curves were plotted using the Kaplan- Meier product-limit estimate. Bracket survival distributions with respect to adhesive material, tooth location, patient's gender and operator, were then compared by means of a log-rank test. Bond failure interface was determined using the Adhesive Remnant Index. RESULTS: Assure recorded a higher bond failure rate (13.8 per cent) than Unite & MIP (7.3 per cent). The corresponding bracket survival curves were found to be significantly different (P < 0.05). Premolars exhibited higher bond failures than incisors and canines (P < 0.001), while half (49.8 per cent) of the total bond failures occurred during the first 2 months of treatment. The predominant mode of failure was within the bonding material. CONCLUSION: The new moisture-resistant adhesive systems under study were found to be clinically efficient, though Assure exhibited a significantly higher bond failure rate than Unite and Transbond MIP. The higher frequency of adhesive failures observed with Assure might indicate a possible weak point at the adhesive-bracket interface.
机译:目的:评价和比较两种新型防潮性正畸粘合剂系统的临床性能:化学固化复合树脂(Unite,3M Unitek,California,USA)与特殊的防潮底漆(Orkbond Mip, 3M Unitek,蒙罗维亚,加利福尼亚州,美国);和氟化物释放的光固化传感器(保证,依赖reliancticsics,Inc.,Itasca,伊利诺伊州,美国)。设计:采用“分嘴”技术的随机对照临床试验。环境:塞萨洛尼基省亚里士多德大学矫正科部。主题(材料)和方法:25例连续启动患者(13名女性和12名男性),需要固定设备正畸治疗。干预措施:四百三十六十六个不锈钢支架与使用两种不同的防潮性正畸粘合剂系统的臼齿进行粘合到所有牙齿上。主要观察措施:为每个粘合剂系统估计9个月期间的债券失败率,并使用Kaplan-Meier产品限制估计绘制相应的支架存活曲线。然后通过对数级测试进行比较胶粘材料,牙齿位置,患者的性别和操作员的支架存活分布。使用粘合剂残余指数测定粘合失效界面。结果:确保记录较高的债券失败率(13.8%),而不是团结和MIP(7.3%)。发现相应的支架存活曲线有显着差异(P <0.05)。前臼齿表现出比牙齿和犬齿的更高的粘合失败(P <0.001),而在治疗的前2个月内发生过量债券失败的一半(49.8%)。主要的失效模式在粘合材料内。结论:发现新的耐湿性粘性粘合剂系统在临床上有效,尽管确保表现出比UNICE和TRANSBOND MIP的粘合率明显更高。用确保观察到的粘合剂故障的较高频率可能表示粘合剂 - 支架界面处的可能弱点。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号