The i-STAT (R) portable clinical analyzer (PCA) provides patient-side results for hematologic, biochemical, and blood gas values when immediate results are desired. This analyzer is commonly used in nondomestic animals; however, validation of this method in comparison with traditional benchtop methods should be performed for each species. In this study, the i-STAT PCA was compared with the Radiometer ABL 800 Flex benchtop analyzer using 24 heparinized whole blood samples obtained from healthy E. maximus. In addition, the effect of sample storage was evaluated on the i-STAT PCA. Analytes evaluated were hydrogen ion concentration (pH), glucose, potassium (K+), sodium (Na+), bicarbonate (HCO3), total carbon dioxide (TCO2), partial pressure of carbon dioxide (PCO2), and ionized calcium (iCa(2+)). Statistical analysis using correlation coefficients, Passing-Bablok regression analysis, and Bland-Altman plots found good agreement between results from samples run immediately after phlebotomy and 4 hr postsampling on the i-STAT PCA with the exception of K+, which is known to change with sample storage. Comparison of the results from the two analyzers at 4 hr postsampling found very strong or strong correlation in all values except K+, with statistically significant bias in all values except glucose and PCO2. Despite bias, mean differences assessed via Bland-Altman plots were clinically acceptable for all analytes excluding K+. Within the reference range for iCa(2+), the iCa(2+) values obtained by the i-STAT PCA and Radiometer ABL 800 Flex were close in value, however in light of the constant and proportionate biases detected, overestimation at higher values and underestimation at lower values of iCa(2+) by the i-STAT PCA would be of potential concern. This study supports the use of the i-STAT PCA for the evaluation of these analytes, with the exception of K+, in the Asian elephant.
机译:I-STAT(R)便携式临床分析仪(PCA)为血液学,生物化学和血气值提供患者侧的结果,当需要立即结果时。该分析仪通常用于非常规动物;然而,应对每个物种进行与传统台式方法相比的这种方法的验证。在本研究中,将I-STAT PCA与辐射计ABL 800 Flex Bebchtop分析仪进行比较,使用由健康的E. Maximus获得的24个肝素化的全血样品。此外,对I-Stat PCA评估了样品存储的效果。评价的分析物是氢离子浓度(pH),葡萄糖,钾(K +),钠(Na +),碳酸氢盐(HCO 3),总二氧化碳(TCO2),二氧化碳(PCO2)的分压和电离钙(ICA(2 +))。使用相关系数的统计分析,通过 - Bablok回归分析和Bland-Altman绘图在Phlebotomy后立即运行的样品的结果与I-STAT PCA上的4小时后,除了K +的情况下,众所周知,这是众所周知的样品存储。在4小时后,两个分析仪的结果比较了4小时后采样的结果发现,除了K +之外的所有值中的所有值都存在非常强烈或强烈的相关性,除了葡萄糖和PCO2之外的所有值中的统计学显着偏差。尽管偏差,通过Bland-Altman图评估的平均差异对于不包括K +的所有分析物,临床上可接受。在ICA(2+)的参考范围内,I-STAT PCA和辐射计ABL 800 Flex获得的ICA(2+)值靠近值,然而,鉴于检测到的恒定和比例偏差,较高值的高度估计通过I-STAT PCA的ICA(2+)的较低值低估并低估将具有潜在的问题。本研究支持使用I-Stat PCA进行这些分析物的评估,除了K +,在亚洲大象中。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号