首页> 外文期刊>Journal of vascular and interventional radiology: JVIR >Dual-Energy CT–Derived Volumetric Iodine Concentration for the Assessment of Therapeutic Response after Microwave Ablation in a Rabbit Model with Intrahepatic VX2 Tumor
【24h】

Dual-Energy CT–Derived Volumetric Iodine Concentration for the Assessment of Therapeutic Response after Microwave Ablation in a Rabbit Model with Intrahepatic VX2 Tumor

机译:用肝内VX2肿瘤在兔模型中微波消融后评估患者治疗反应的双能CT衍生体积碘浓度

获取原文
获取原文并翻译 | 示例
   

获取外文期刊封面封底 >>

       

摘要

PurposeTo evaluate whether changes in volumetric iodine concentration (VIC) could serve as a suitable predictor of therapeutic response to microwave (MW) ablation in a rabbit intrahepatic VX2 tumor model. Materials and MethodsSixteen intrahepatic VX2 tumors were transplanted in 8 New Zealand White rabbits treated with MW ablation. Contrast-enhanced dual-energy CT scans were obtained at baseline and follow-up. Therapeutic response assessment by modified Response Evaluation Criteria In Solid Tumors (mRECIST), Choi criteria, and VIC changes was performed. An intraclass correlation coefficient (ICC) was used to characterize consistency of assessment results among the criteria used. Technical success was evaluated with explant pathologic findings as a reference. Correlations between technical success and variations in diameter, CT density, and VIC were analyzed. ResultsDisease control was observed in 4, 8, and 10 of the 16 tumors per mRECIST, Choi criteria, and VIC changes, respectively. VIC exhibited strong consistency (ICC?= 0.807,P< .0001) with Choi criteria. According to explant pathology, technical success was achieved in 10 of the 16 tumors. There was a moderate correlation between VIC changes and technical success (r?= 0.532,P?= .034), and no correlation was found between technical success and variations in diameter or CT density. ConclusionsCompared with mRECIST and Choi criteria, dual-energy CT–derived VIC allowed for better prediction of therapeutic response after MW ablation and could provide a potential imaging biomarker of tumor response to MW ablation in patients with hepatocellular carcinoma.
机译:purposeto评估体积碘浓度(ViC)的变化是否可以作为对兔肝内Vx2肿瘤模型中的微波(MW)消融的治疗响应的合适预测因子。用MW消融处理的8个新西兰白兔移植材料和方法肝内VX2肿瘤。对比度增强的双能CT扫描是在基线和随访中获得的。通过修饰的响应评估标准进行实体肿瘤(MRECIST),CHOI标准和VIC变化的治疗响应评估。脑内相关系数(ICC)用于表征评估结果的一致性在使用的标准中。用消遣剂病理发现评估了技术成功作为参考。分析了技术成功与直径,CT密度和ViC的变化之间的相关性。在每个MRECIST,CHOI标准和VIC变化中分别观察到16,8和10的结果对照。 VIC与CHOI标准表现出强大的一致性(ICC?= 0.807,P <.0001)。根据外植化病理学,在16个肿瘤中的10个中取得了技术成功。 VIC变化与技术成功之间存在适中的相关性(R?= 0.532,P?= .034),并且在技术成功和直径或CT密度的变化之间没有发现相关性。结论与MRECIST和CHOI标准的分析,双能CT衍生的VIC允许更好地预测MW消融后的治疗响应,并且可以提供肝细胞癌患者MW消融的肿瘤反应的潜在成像生物标志物。

著录项

  • 来源
  • 作者单位

    Department of Radiology The First Af?liated Hospital of China Medical University;

    Department of Radiology The First Af?liated Hospital of China Medical University;

    Department of Radiology The First Af?liated Hospital of China Medical University;

    Department of Radiology The First Af?liated Hospital of China Medical University;

    Department of Biological Technology China Medical University–The Queen’s University of Belfast;

    Department of Radiology The First Af?liated Hospital of China Medical University;

    Department of Radiology The First Af?liated Hospital of China Medical University;

  • 收录信息
  • 原文格式 PDF
  • 正文语种 eng
  • 中图分类 放射医学;
  • 关键词

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号