The objective of this study was to examine the microbiological and physico-chemical properties of different types of drinking water used. The cross-sectional type study was carried out between January 1 and April 30, 2016. The samples acquired for the study from 50 packages, 50 tap water taps, and 50 residential treatment devices were examined both microbiologically and biochemically. The pH values varied between 5.57 and 8.26. pH values of tap and packaged waters were all determined to be proper, and improperly low pH values were determined in 25 of the samples acquired from the residential treatment devices. It was determined that amounts of fluoride, chloride, nitrate, nitrite, arsenic, and ammonium were all acceptable. Fluoride amounts were determined to be high at a statistically significant level in packaged and residential treatment device water (p = 0.000). Escherichia coli was determined in 10% of tap water and 2% of packaged water. Microbiological contaminations of the samples collected after the pump-faucet and water fountain were determined to be greater in comparison with those of samples collected directly from packaged waters. It was determined that the residential treatment process is applied more on drinkable waters. The purification of water causes significant physico-chemical changes.
机译:本研究的目的是检查使用不同类型的饮用水的微生物和物理化学性质。在2016年1月1日至4月30日之间进行了横截面类型研究。用于从50个包装,50个自来水抽头和50种住宅处理装置中获得的样品进行微生物学和生物化学。 pH值在5.57和8.26之间变化。龙头和包装水的pH值均确定为适当的,并且在从住宅治疗装置中获得的25个样品中测定不正确的pH值。确定氟化物,氯化物,硝酸盐,亚硝酸盐,砷和铵量都是可接受的。测定氟化物量高,在包装和住宅处理装置水中的统计学显着水平高(P = 0.000)。大肠杆菌在灌水水中的10%和2%的包装水中测定。与直接从包装水收集的样品相比,确定在泵龙头和喷泉之后收集的样品的微生物污染。确定住宅治疗过程适用于饮用水。水的纯化导致显着的物理化学变化。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号