首页> 外文期刊>Journal of voice: official journal of the Voice Foundation >Auditory-Perceptual Evaluation of Voice Quality of Cochlear-implanted and Normal-hearing Individuals: A Reliability Study
【24h】

Auditory-Perceptual Evaluation of Voice Quality of Cochlear-implanted and Normal-hearing Individuals: A Reliability Study

机译:耳蜗植入和正常听力人员语音质量的听觉感知评估:可靠性研究

获取原文
获取原文并翻译 | 示例
       

摘要

Summary Objective This study aimed to present an experience in rating voices of adults with normal hearing and adults with cochlear implants and critically examine the outcomes, discussing pros and cons of the methodology used. Study design This is a cross-sectional, prospective study. Methods One hundred and fifty voice samples, consisting of 50 sustained vowels, 50 samples of connected speech, and 50 samples of conversational speech, belonging to 25 adults with hearing impairment with cochlear implants and 25 adults with normal hearing, were perceptually analyzed for inter-rater agreement and intra-rater reliability. Three experienced judges rated the voice samples using visual analog scales of parameters considered relevant for cochlear-implanted population such as articulation, intonation, and resonance. The raters participated in three training sessions for calibration and had 1 month to complete the ratings individually. Twenty percent of the samples were repeated randomly to verify intra-rater reliability. The levels of agreement and reliability were verified using the interclass correlation coefficient. Results The inter-rater agreement varied widely across the parameters and speech tasks, from poor to excellent agreement. The only parameter for which the raters maintained consistently good or excellent agreement for all groups and emissions was the pitch. For intra-rater reliability, two of the raters presented excellent reliability for most parameters across all of the speech tasks, whereas one rater presented more inconsistencies. Conclusions In this reliability study, factors such as extensive deadline for the auditory perceptual evaluation, lack of periodic recalibration, speech tasks, and familiarity with the population studied were identified as factors that contributed to inconsistent reliability results.
机译:摘要目的本研究旨在展示具有正常听力和成人的成年人的评级声音,并批判性检查结果,讨论所用方法的利弊。研究设计这是一个横断面的前瞻性研究。方法三百五十个语音样本,由50个持续的元音,50个样本的连接语音样本以及50个具有与耳蜗植入物和25名具有正常听力的障碍障碍的25个成年人的对话演讲,进行了感知互连评估协议和帧内可靠性。三位经验的法官使用视觉模拟尺度的语音样本评定了视觉模拟尺度,该参数被认为是与耳蜗植入的群体,例如关节,语调和共振。评估者参加了三次校准校准,并有1个月单独完成评级。随机重复20%的样品以验证帧内可靠性。使用杂交相关系数来验证协议和可靠性的水平。结果税率协议广泛多种参数和语音任务,从差到良好的协议。评估者对所有群体和排放保持始终如一的良好或良好协议的唯一参数是音高。对于帧内可靠性,其中两位评估者对所有语音任务的大多数参数呈现出优异的可靠性,而一名评估者则提出了更多不一致。结论在这种可靠性研究中,诸如广泛的听觉感知评估的因素,缺乏定期重新校准,语音任务和研究人口的熟悉程度被确定为导致可靠性效果不一致的因素。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号