...
首页> 外文期刊>Journal of Veterinary Diagnostic Investigation >Interlaboratory comparison of heavy metal testing in animal diagnostic specimens and feed using inductively coupled plasma–mass spectrometry
【24h】

Interlaboratory comparison of heavy metal testing in animal diagnostic specimens and feed using inductively coupled plasma–mass spectrometry

机译:使用电感耦合等离子体质谱法对动物诊断标本中重金属检测的逆向比较

获取原文
获取原文并翻译 | 示例
           

摘要

We compared inductively coupled plasma–mass spectrometry (ICP-MS) test results for the analysis of heavy metals (As, Ba, Cd, Hg, Pb, and Se) in pet foods and routine veterinary diagnostic specimens using intralaboratory and interlaboratory comparisons. Four laboratories, 1 principal laboratory and 3 collaborating laboratories, conducted instrument comparison (limit of detection [LOD], limit of quantification [LOQ], and linear dynamic range [LDR] on 24 data sets), in-house method comparison (accuracy and precision on 120 data sets), and interlaboratory comparison (reproducibility on 528 data sets using Horwitz equation analysis). Matrices tested included 2 types of pet food jerky treats (chicken and sweet potato), bovine blood, and bovine liver and kidney. The instrument comparison study confirmed that ICP-MS provided the sensitivity necessary for the analysis of all heavy metals tested at concentrations below the level of concern for routine diagnostic testing. The “in-house” method comparison samples, spiked at low (0.04 μg/g), medium (0.4 μg/g), and high (8.0 μg/g; note: the high validation level spike for mercury was 2 μg/g) concentration levels, indicated that ICP-MS can meet U.S. FDA acceptance criteria for both accuracy (90–105% recovery) and precision (< 6% coefficient of variation). The interlaboratory comparison studies showed that ICP-MS is a reproducible method for the analysis of heavy metals (HorRat value of 0.5–2.0) except for mercury in one laboratory, which used a different sample preparation method (open block rather than microwave digestion). Overall, our study showed that ICP-MS is a reproducible method for the analysis of heavy metals in spite of minor differences in methodology.
机译:我们将电感耦合耦合等离子体质谱(ICP-MS)测试结果与intralaboratory和Interlaboratory比较分析PET食品和常规兽医诊断标本中的重金属(AS,BA,CD,HG,PB和SE)的分析。四个实验室,1个主实验室和3个协作实验室,进行了仪器比较(检测极限[LOD],量化限制[LOQ],24数据集的线性动态范围[LDR]),内部方法比较(准确性和120数据集的精度)和使用Horwitz方程分析的2508个数据集上的再标准比较)。测试的基质包括2种类型的宠物食品生涩零食(鸡肉和甘薯),牛血和牛肝和肾脏。仪器比较研究证实,ICP-MS为分析在低于常规诊断检测的关注水平以下的浓度下测试的所有重金属所需的敏感性。 “内部”方法比较样品,以低(0.04μg/ g),培养基(0.4μg/ g)和高(8.0μg/ g;注意:汞的高验证水平尖峰为2μg/ g )浓度水平,表明ICP-MS可以满足美国FDA验收标准,用于精度(回收率为90-105%)和精度(<6%的变化系数)。互上的比较研究表明,除了一个实验室中的汞外,ICP-MS是一种可再现的方法,用于分析重金属(0.5-2.0),除了一个实验室中的汞,它使用不同的样品制备方法(开放块而不是微波消解)。总体而言,我们的研究表明,尽管方法论细微差异,ICP-MS是一种可重复的分析重金属的方法。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号