...
首页> 外文期刊>Journal of veterinary cardiology >Comparison of longitudinal myocardial tissue velocity, strain, and strain rate measured by two-dimensional speckle tracking and by color tissue Doppler imaging in healthy dogs.
【24h】

Comparison of longitudinal myocardial tissue velocity, strain, and strain rate measured by two-dimensional speckle tracking and by color tissue Doppler imaging in healthy dogs.

机译:纵向心肌组织速度,菌株和应变率的比较,由二维散斑跟踪和健康犬色组织多普勒成像测量。

获取原文
获取原文并翻译 | 示例
   

获取外文期刊封面封底 >>

       

摘要

Objectives - Two-dimensional speckle tracking (2D-ST) is a new method to measure tissue velocity (TV), strain and strain rate (SR), but it is unclear if results are comparable to color tissue Doppler imaging (TDI). The objective was therefore to compare the two modalities 2D-ST and TDI. Animals - 100 healthy dogs. Methods - TDI images were acquired from the interventricular septal wall (IVS) and the left ventricular free wall (LVFW) to measure longitudinal TV, strain, and SR, and grayscale images were collected for 2D-ST analysis. A software program was developed, that allowed extraction of single points (SP) from the 2D-ST data set to compare SP with averages of segments (AOS) results, which are usually displayed by the 2D-ST software. Results - A good agreement was found between AOS and SP measurements using 2D-ST. Although most data were within limits of agreement, significant differences were found between TDI and 2D-ST measurements for selected parameters. The differences were small in the IVS, but higher and of clinical relevance in the LVFW. 2D-ST was feasible and reproducible in the IVS, but less reliable in the LVFW. Conclusions - 2D-ST and color TDI can be used interchangeably in the IVS, but the methods reveal different results in the LVFW.Digital Object Identifier http://dx.doi.org/10.1016/j.jvc.2010.08.001
机译:目标 - 二维散斑跟踪(2D-ST)是测量组织速度(TV),应变和应变率(SR)的新方法,但如果结果与颜色组织多普勒成像(TDI)相当,则目前尚不清楚。因此,目的是比较2D-ST和TDI的两种方式。动物 - 100只健康狗。方法 - 从间隔内壁(IVS)和左心室自由壁(LVFW)获取TDI图像以测量纵向电视,菌株和SR,并收集灰度图像,用于2D-ST分析。开发了一种软件程序,允许从2D-ST数据集中提取单点(SP),以将SP与段的平均值(AOS)结果进行比较,这通常由2D-ST软件显示。结果 - 使用2D-ST的AOS和SP测量在AOS和SP测量之间发现了一个良好的一致。虽然大多数数据都在一致的范围内,但在TDI和2D-ST测量中发现了显着的差异,用于选定参数。 IVS中的差异很小,但在LVFW中临床相关性。在IVS中,2D-ST是可行和可重复的,但在LVFW中不太可靠。结论 - 2D-ST和COLOR TDI可以在IVS中可互换使用,但方法显示LVFWW.DIGITAL对象标识符http://dx.doi.org/10.1016/j.jvc.201010.08.001

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号